datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

TDF8599 데이터 시트보기 (PDF) - NXP Semiconductors.

부품명
상세내역
일치하는 목록
TDF8599 Datasheet PDF : 52 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
NXP Semiconductors
TDF8599
Class-D power amplifier with load diagnostics
In I2C-bus mode, DC offsets generate a voltage shift around the bias voltage. When the
voltage shift exceeds threshold values, the offset alarm bit DB1[D2] is set and if bit
IB1[D7] is set, diagnostic information is also given. Any detected offset shuts down both
channels when bit IB2[D7] is not set. To restart the TDF8599 in I2C-bus mode, pin EN
must be toggled or DCP disabled by connecting pin DCP to pin GND.
In non-I2C-bus mode, when an offset is detected, DCP always gives diagnostic
information on pin DIAG and shuts down both channels. Connecting pin DCP to pin GND
disables DCP.
8.5.6 Supply voltages
UnderVoltage Protection (UVP) is activated when the supply voltage drops below the UVP
threshold (typically 7.5 V). UVP triggers the UVP circuit causing the system to first mute
and then stop switching. When the supply voltage rises above the threshold level, the
system restarts.
OverVoltage Protection (OVP) is activated when the supply voltage exceeds the OVP
threshold (typically 27 V). The OVP (or load dump) circuit is activated and the power
stages are shutdown. An overview of all protection circuits and the amplifier states is
given in Table 10.
8.5.7 Overview of protection circuits and amplifier states
Table 10. Overview of TDF8599 protection circuits and amplifier states
Protection circuit name
Amplifier state
Complete
shutdown
Channel
shutdown
TFP
N[2]
N[2]
OTP
Y
N
OCP
N
Y
WP
N
Y
DCP
Y
N
UVP
Y
N
OVP
Y
N
Restart[1]
Y[3]
Y[3]
Y[4]
Y
N[5]
Y[6]
Y
[1] When fault is removed.
[2] Amplifier gain depends on the junction temperature and size of the heat sink.
[3] TFP influences restart timing depending on heat sink size.
[4] Shorted load causes a restart of the channel every 50 ms.
[5] Latched protection is reset by toggling the pin EN or by disabling DCP in I2C-bus mode.
[6] In I2C-bus mode deep supply voltage drops will cause a Power-On Reset (POR). The restart requires an
I2C-bus command.
TDF8599_1
Product data sheet
Rev. 01 — 13 November 2008
© NXP B.V. 2008. All rights reserved.