TDF8599
Class-D power amplifier with load diagnostics
8.5.4 Window protection
Window Protection (WP) checks the PWM output voltage before switching from Standby
mode to Mute mode (outputs switching) and is activated as follows:
During the start-up sequence:
When the TDF8599 is switched from standby to mute (td(stb-mute)). When a short
circuit on one of the output terminals (i.e. between VP and GND) is detected, the
start-up procedure is interrupted and the TDF8599 waits for open circuit outputs.
No large currents flow in the event of a short circuit to the supply lines because the
check is performed before the power stages are enabled.
During operation:
A short to one of the supply lines activates OCP causing the amplifier channel to
shutdown. After 50 ms the amplifier channel restarts and WP is activated.
However, the corresponding amplifier channel will not start-up until the supply line
short circuit has been removed.
8.5.5 DC Protection
DC Protection (DCP) is activated when the DC content in the demodulated output voltage
exceeds a set threshold (typically 2 V). DCP is active in both Mute mode and Operating
mode. False triggering of the DCP by low frequencies in the audio signal is prevented
using the external capacitor (CF) to generate a cut-off frequency as shown in Figure 15.
OUT1P
OUT1N
OUT2P
V to I
V to I
IB1[D6]
IB2[D6]
Vref
50 k
OUT2N
DCP
DB1[D7]
SQ
IB1[D7]
DIAG
S4
IB2[D7]
switch off channels
S3
Fig 15. DC offset protection and diagnostic output