Low-Power, 8-Channel,
Serial 10-Bit ADC
CLOCK
MODE
SHDN
DIN
INTERNAL
SETS EXTERNAL
CLOCK MODE
SXXXXX11
EXTERNAL
SX X XXX0 1
SETS FAST
POWER-DOWN
MODE
SETS EXTERNAL
CLOCK MODE
S XX XXX1 1
EXTERNAL
DOUT
MODE
DATA VALID
(10 + 2 DATA BITS)
POWERED UP
DATA VALID
(10 + 2 DATA BITS)
VALID DATA INVALID
FAST POWERED UP
POWER-DOWN
FULL
POWER-
DOWN
POWERED
UP
Figure 12a. Timing Diagram Power-Down Modes, External Clock
CLOCK
MODE
SETS INTERNAL
CLOCK MODE
INTERNAL CLOCK MODE
SETS FULL
POWER-DOWN
DIN
SXXXXX10
SX X XXX0 0
S
DOUT
DATA VALID
DATA VALID
SSTRB
MODE
CONVERSION
POWERED UP
CONVERSION
FULL
POWER-DOWN
POWERED
UP
Figure 12b. Timing Diagram Power-Down Modes, Internal Clock
Power-Down
Choosing Power-Down Mode
You can save power by placing the converter in a
low-current shutdown state between conversions.
Select full power-down or fast power-down mode via
bits 1 and 0 of the DIN control byte with SHDN either
high or floating (see Tables 3 and 6). Pull SHDN low at
any time to shut down the converter completely. SHDN
overrides bits 1 and 0 of DIN word (see Table 7).
Full power-down mode turns off all chip functions that
draw quiescent current, typically reducing IDD to 2µA.
Fast power-down mode turns off all circuitry except the
bandgap reference. With the fast power-down mode, the
supply current is 30µA. Power-up time can be shortened
to 5µs in internal compensation mode.
In both software shutdown modes, the serial interface
remains operational, however, the ADC will not convert.
Table 5 illustrates how the choice of reference-buffer
compensation and power-down mode affects both
power-up delay and maximum sample rate.
In external compensation mode, the power-up time is
20ms with a 4.7µF compensation capacitor when the
capacitor is fully discharged. In fast power-down, you
can eliminate start-up time by using low-leakage capaci-
______________________________________________________________________________________ 15