CXD2500BQ
§1 Meanings of Data Set at Command Addresses
$4X Command
Command
AS3
AS2
CANCEL
0
0
FOCUS-ON
0
1
1 TRACK JUMP
1
0
10 TRACK JUMP
1
0
2N TRACK JUMP
1
1
M TRACK MOVE
1
1
AS1
AS0
0
0
1
1
0
RXF
1
RXF
0
RXF
1
RXF
RXF=0 FORWARD
RXF=1 REVERSE
• If a Focus-ON command ($47) is canceled during execution, $02 is issued and the auto sequence operation
is discontinued.
• If a Track Jump or Track Move command ($48 to $4F) is canceled during execution, the auto sequence
operation is discontinued.
$5X Command
Used to set timers for the auto sequencer.
Timers set: A, E, C, and B
Command
D3
Blind(A, E), Overflow(C)
0.18 ms
Brake(B)
0.36 ms
Example:
D2=D0=1, D3=D1=0 (Initial Reset)
A=E=C=0.112 ms
B=0.225 ms
D2
0.09 ms
0.18 ms
D1
0.045 ms
0.09 ms
D0
0.022 ms
0.045 ms
$6X Command
Used to set a timer for the auto sequencer.
Timer set: D
Command
D3
KICK (D)
11.6 ms
Example: D3=0 D2=D1=D0=1 (Initial Reset)
D=10.15ms
D2
5.8 ms
D1
2.9 ms
D0
1.45 ms
$7X Command
Used to set the number of auto sequencer track jumps/moves.
Command
Data3
Data 2
D3 D2 D1 D0 D3 D2 D1 D0
Data 3
D3 D2 D1 D0
Data 4
D3 D2 D1 D0
Auto sequencer track
jump number setting
215 214 213 212 211 210 29 28
27 26 25 24
23 22 21 20
This command sets the value of “N” for 2N track jump and M track move execution using the auto sequencer.