!Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
C02E.pdf
Nov.27,2017
!Caution
Continued from the preceding page.
2. Other
2-1. In an Emergency
(1) If the equipment should generate smoke, fire, or
smell, immediately turn o or unplug the
equipment.
If the equipment is not turned o or unplugged, the
hazards may be worsened by supplying continuous
power.
(2) In this type of situation, do not allow face and
hands to come in contact with the capacitor or
burns may be caused by the capacitor's high
temperature.
2-2. Disposal of Waste
When capacitors are disposed of, they must be burned
or buried by an industrial waste vendor with the
appropriate licenses.
2-3. Circuit Design
(1) Addition of Fail Safe Function
Capacitors that are cracked by dropping or bending
of the board may cause deterioration of the
insulation resistance, and result in a short.
If the circuit being used may cause an electrical
shock, smoke or fire when a capacitor is shorted,
be sure to install fail-safe functions, such as a fuse,
to prevent secondary accidents.
(2) Capacitors used to prevent electromagnetic
interference in the primary AC side circuit, or as a
connection/insulation, must be a safety standard
certified product, or satisfy the contents stipulated
in the Electrical Appliance and Material Safety Law.
Install a fuse for each line in case of a short.
(3) The GJM, GMA, GMD, GQM, GR3, GRJ, GRM, KR3,
KRM, LLA, LLL, LLM, LLR, NFM and ZRB series are
not safety standard certified products.
2-4. Test Condition for AC Withstanding Voltage
(1) Test Equipment
Test equipment for AC withstanding voltage
should be made with equipment capable of
creating a wave similar to a 50/60Hz sine wave.
(2) Voltage Applied Method
The capacitor's lead or terminal should be firmly
connected to the output of the withstanding
voltage test equipment, and then the voltage
should be raised from near zero to the test
voltage.
If the test voltage is applied directly to the
capacitor without raising it from near zero, it
should be applied with the zero cross. *At the end
of the test time, the test voltage should be
reduced to near zero, and then capacitor's lead or
terminals should be taken o the output of the
withstanding voltage test equipment.
If the test voltage applied directly to the
capacitor without raising it from near zero, surge
voltage may occur and cause a defect.
*ZERO CROSS is the point where voltage sine wave
passes 0V. - See the figure at right -
Voltage sine wave
0V
zero cross
2-5. Remarks
Failure to follow the cautions may result, worst case,
in a short circuit and smoking when the product is
used.
The above notices are for standard applications and
conditions. Contact us when the products are used in
special mounting conditions.
Select optimum conditions for operation as they
determine the reliability of the product a er
assembly.
The data herein are given in typical values, not
guaranteed ratings.