LD39300
Typical application circuits
3
Typical application circuits
CI and CO capacitors must be placed as close as possible to the IC pins.
Figure 3: LD39300 fixed version with inhibit
Inhibit pin is not internally pulled down/up then it must not be left floating. It
disables the device when connected to GND or to a positive voltage less than
0.3 V.
Figure 4: LD39300 adjustable version
Set R2 as close as possible to 4.7 KΩ.
DocID13160 Rev 3