datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

MPVZ5004 데이터 시트보기 (PDF) - Freescale Semiconductor

부품명
상세내역
일치하는 목록
MPVZ5004 Datasheet PDF : 22 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Operating Characteristics
Pressure
Table 1. Operating Characteristics (VS = 5.0 VDC, TA = 25°C unless otherwise noted, P1 > P2)
Characteristic
Symbol
Min
Typ
Max
Units
Pressure Range
Supply Voltage(1)
Supply Current
Span @ 306 mm H2O (3 kPa)(2)
Full Scale Span @ 400 mm H2O (3.92 kPa)(2)
Offset(3)
Sensitivity
Accuracy (4) (5)
0 to 100 mm H2O (10 to 60°C)
100 to 400 mm H2O (10 to 60°C)
0 to 400 mm H2O (10 to 60°C
POP
VS
IS
VFSS
VOFF
V/P
0
4.75
0.75
3.92
kPa
400
mm H2O
5.0
5.25
VDC
10
mAdc
3.0
V
4.0
1.0
1.25
V
1.0
V/kPa
±1.5
%VFSS with auto
zero
±2.5
%VFSS with auto
zero
±6.25
%VFSS without
auto zero
1. Device is ratiometric within this specified excitation range.
2. Span is defined as the algebraic difference between the output voltage at specified pressure and the output voltage at the minimum rated
pressure.
3. Offset (Voff) is defined as the output voltage at the minimum rated pressure.
4. Accuracy (error budget) consists of the following:
Linearity:Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis:Output deviation at any temperature within the operating temperature range, after the temperature is cycled to and
from the minimum or maximum operating temperature points, with zero differential pressure applied.
Pressure Hysteresis:Output deviation at any pressure within the specified range, when this pressure is cycled to and from the minimum or
maximum rated pressure, at 25°C.
Offset Stability:Output deviation, after 1000 temperature cycles, -30 to 100°C, and 1.5 million pressure cycles, with minimum rated pressure
applied.
TcSpan:Output deviation over the temperature range of 10 to 60°C, relative to 25°C.
TcOffset:Output deviation with minimum rated pressure applied, over the temperature range of 10 to 60°C, relative to 25°C.
Variation from Nominal:The variation from nominal values, for Offset or Full Scale Span, as a percent of VFSS, at 25°C.
5. Auto Zero at Factory Installation: Due to the sensitivity of the MPVZ5004G, external mechanical stresses and mounting position can affect
the zero pressure output reading. Autozeroing is defined as storing the zero pressure output reading and subtracting this from the device's
output during normal operations. Reference AN1636 for specific information. The specified accuracy assumes a maximum temperature
change of ±5°C between autozero and measurement.
Sensors
Freescale Semiconductor
MPXV5004G
3

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]