datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

BR24G256-3AG 데이터 시트보기 (PDF) - ROHM Semiconductor

부품명
상세내역
일치하는 목록
BR24G256-3AG Datasheet PDF : 39 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
BR24Gxxx-3A (128K 256K 1M)
Read Command
1. Read Cycle
Read cycle is when data of EEPROM is read. Read cycle could be random read cycle or current read cycle. Random
read cycle is a command to read data by designating a specific address, and is used generally. Current read cycle is a
command to read data of internal address register without designating an address, and is used when to verify just after
write cycle. In both the read cycles, sequential read cycle is available where the next address data can be read in
succession.
S
W
S
T
R
T
R
S
A
R
T
SLAVE
ADDRESS
I
T
E
1st WORD
ADDRESS(n)
2nd WORD
ADDRESS(n)
A
R
T
SLAVE
ADDRESS
E
A
D
DATA(n)
T
O
P
SDA
LINE
1 0 1 0 A2A1A0
WAWA
15 14
WA
0
1 0 1 0 A2A1A0
D7
(1) As for WA14, BR24G128-3A become dont care.
D0
As for WA15, BR24G128/256-3A become dont care.
00
00
RA
Note)
/C
(1)
A
C
A
RA
C
/C
A
C
WK
K
K
WK
K
Figure 41. Random Read Cycle
SDA
LINE
S
T
R
A
E
R
SLAVE
A
T ADDRESS D
S
T
O
DATA(n)
P
1 0 1 0 A2A1A0
D7
0
Note)
RA
/C
WK
D0
A
C
K
Figure 42. Current Read Cycle
S
T
A
R
T
SLAVE
ADDRESS
R
E
A
D
DATA(n)
SDA
LINE
1 0 1 0 A2 A1A0
D7
D0
00
RA
A
Note
/C
WK
C
K
S
T
DATA(n+x)
O
P
D7
D0
A
A
C
C
K
K
Figure 43. Sequential Read Cycle (in the case of current read cycle)
(1) In random read cycle, data of designated word address can be read.
(2) When the command just before current read cycle is random read cycle, current read cycle (each including
sequential read cycle), data of incremented last read address (n)-th, i.e., data of the (n+1)-th address is output.
(3) When ACK signal 'LOW' after D0 is detected, and stop condition is not sent from master (μ-COM) side, the next
address data can be read in succession.
(4) Read cycle is ended by stop condition where 'H' is input to ACK signal after D0 and SDA signal goes from ‘L’ to
‘H’ while at SCL signal is ‘H’.
(5) When 'H' is not input to ACK signal after D0, sequential read gets in, and the next data is output.
Therefore, read command cycle cannot be ended. To end read command cycle, be sure to input 'H' to ACK signal
after D0, and the stop condition where SDA goes from ‘L’ to ‘H’ while SCL signal is 'H'.
(6) Sequential read is ended by stop condition where 'H' is input to ACK signal after arbitrary D0 and SDA is asserted
from ‘L’ to ‘H’ while SCL signal is 'H'.
Note)
(1)
1 0 1 0 A2A1A0
(1) In BR24G1M-3A, A0 becomes P0.
00
Figure 44. Difference of Slave Address of Each Type
www.rohm.com
© 2014 ROHM Co., Ltd. All rights reserved.
TSZ22111 15 001
19/36
TSZ02201-0R2R0G100020-1-2
24.Mar.2020 Rev.008