BR24A□□-WM series
Technical Note
Notes on write cycle continuous input
SDA
LINE
S
T
A
R
T
SLAVE
ADDRESS
W
R
I
T
E
WORD
ADDRESS(n)
DATA(n)
*1
1 0 1 0 A2A1A0 WA
7
WA
0 D7
D0
RA
A
A
Note)
/C
C
C
WK
K
K
Fig.40 Page write cycle
Note)
*1 *2 *3
1 0 1 0 A 2A 1A 0
Fig.42 Difference of each type of slave address
DATA(n+7)**23
At STOP (stop bit),
write starts.
S
T
O
P
S
T
A
R
T
D0
1 0 10
A
C
Next command
K
tWR(maximum : 5ms)
*1 BR24A01A-WM beCcomommaensd iDs noont atccceaprteed. for this period.
*2 BR24A04-WM, BR24A08-W, and BR24A16-WM become (n+15).
*3 BR24A32-WM and BR24A64-WM become (n+31).
*1 In BR24A16-WM, A2 becomes P2.
*2 In BR24A08-WM, BR24A16-WM, A1 becomes P1.
*3 In BR24A04-WM, A0 becomes PS, and in BR24A08-WM
and in BR24A16-WM, A0 becomes P0.
Notes on page write cycle
List of numbers of page write
Number of Pages
Product
number
8Byte
BR24A01A-WM
BR24A02-WM
16Byte
BR24A04-WM
BR24A08-WM
BR24A16-WM
32Byte
BR24A32-WM
BR24A64-WM
The above numbers are maximum bytes for respective types.
Any bytes below these can be written.
In the case BR24A02-WM, 1 page=8bytes, but the page write cycle write time is 5ms at maximum for 8byte bulk write.
It does not stand 5ms at maximum × 8byte=40ms(Max.).
Internal address increment
Page write mode (in the case of BR24A02-WM)
WA7 ----- WA4 WA3
0 ----- 0
0
0 ----- 0
0
0 ----- 0
0
WA2
0
0
0
WA1
0
0
1
WA0
0
1
0
Increment
06h
0
0
-----
-----
0
0
0 ----- 0
0
1
1
0
0
1
1
1
0
0
0
0
Significant bit is fixed.
No digit up
For example, when it is started from address 06h,therefore, increment is made as below,
06h 07h 00h 01h ---, which please note.
*06h・・・06 in hexadecimal, therefore, 00000110 becomes a binary number.
Write protect (WP) terminal
Write protect (WP) function
When WP terminal is set VCC (H level), data rewrite of all addresses is prohibited. When it is set GND (L level), data rewrite of
all address is enabled. Be sure to connect this terminal to VCC or GND, or control it to H level or L level. Do not use it open.
At extremely low voltage at power ON / OFF, by setting the WP terminal 'H', mistake write can be prevented.
During tWR, set the WP terminal always to 'L'. If it is set 'H', write is forcibly terminated.