M95640, M95320
DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, and the DC and AC charac-
teristics of the device. The parameters in the DC
and AC Characteristic tables that follow are de-
rived from tests performed under the Measure-
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parame-
ters.
Table 10. Operating Conditions (M95320 and M95640)
Symbol
Parameter
Min.
Max.
Unit
VCC
Supply Voltage
4.5
5.5
V
Ambient Operating Temperature (Device Grade 6)
–40
85
°C
TA
Ambient Operating Temperature (Device Grade 3)
–40
125
°C
Table 11. Operating Conditions (M95320-W and M95640-W)
Symbol
Parameter
Min.
Max.
Unit
VCC
Supply Voltage
2.5
5.5
V
Ambient Operating Temperature (Device Grade 6)
–40
85
°C
TA
Ambient Operating Temperature (Device Grade 3)
–40
125
°C
Table 12. Operating Conditions (M95320-R and M95640-R)
Symbol
Parameter
Min. 1
Max. 1
VCC
Supply Voltage
1.8
5.5
TA
Ambient Operating Temperature
–40
85
Note: 1. This product is under development. For more information, please contact your nearest ST sales office.
Table 13. Operating Conditions (M95320-S and M95640-S)
Symbol
Parameter
Min. 1
Max. 1
VCC
Supply Voltage
1.65
5.5
TA
Ambient Operating Temperature
–40
85
Note: 1. This product is under development. For more information, please contact your nearest ST sales office.
Table 14. AC Measurement Conditions
Symbol
Parameter
CL
Load Capacitance
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Reference Voltages
Note: Output Hi-Z is defined as the point where data out is no longer driven.
Min.
Typ.
Max.
30
50
0.2VCC to 0.8VCC
0.3VCC to 0.7VCC
Unit
V
°C
Unit
V
°C
Unit
pF
ns
V
V