Note: the time outputs and the enrolment reader are not set to their default settings.
Relay Outputs
Badge 1 – Access Level 01
Badge 2 – Access Level 02
relays
Badge 3 – Access Level 03
Controller built-in reader activates relay 1
Remote reader 1 activates relay 1
Controller built-in reader activates no
Remote reader 2 activates relay 2
Controller built-in reader activates relay 1
Remote reader 1 activates relay 1
Remote reader 2 activates relay 2
Reset to Factory Default Values
Cut the power on the DG502 unit
Place the jumper on ST1, 2-3 position
Power on the DG502, the LED is still off
Remove the jumper from ST1, 2-3 position, the LED flashes orange
Wiring of the Remote Readers
Follow the schematic on page 1 to connect remote reader 1 to the controller. Connect terminals 2, 3, 4,
5, 12 and V from the controller directly to the terminals on the remote reader 1. Terminal 6 on the
controller is connected to terminal 1 of remote reader 1.
For remote reader 2, connect in parallel terminals 2, 3, 4, 5, 12 and V from the controller unit. Terminal 1
on the controller is connected to terminal 1 of remote reader 2.
To power the remote readers use a different power supply or use the 12V output from the
controller (At the right hand completely it is the inputs 12V of the controller. The 12V at
the left of the other 12V is the output).