datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

DG502U 데이터 시트보기 (PDF) - Unspecified

부품명
상세내역
일치하는 목록
DG502U
ETC
Unspecified ETC
DG502U Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
Edition 12/2005
Change the Master Code
1. Enter the master code twice (for the first use the master code default value
is 12345). 2 beeps and the orange LED lights on confirming that you are in
programming mode.
2. Enter *3 then the 5-digit new master code. The LED goes off during 1 second
and an audible beep indicates that the new master code is memorised.
3. Press # to exit from the programming mode. 2 beeps confirm that you went
back to the reading mode.
4 beeps indicate a data computing error.
Time outputs, Enrolment Reader and Access Level
Enter the master code twice (for the first use the master code default value is
12345). 2 beeps and the orange LED lights on confirm the entry in programming
mode.
Enrolment reader
Time output relay 1
Enter 0, then 00 to select the built-in reader of the controller as the
enrolment unit.
Press 0, then 01 remote reader 1 as the enrollment unit.
The LED lights off during 1 second and an audible beep indicates
the validation of the enrolment reader.
In stand-by mode, if the enrolment reader is the controller
built-in reader all the readers can be used but if the enrolment
reader is the remote reader 1 then only the 2 remote reader can
be used.
Enter 1, then the time relay in second:
01 equal 1 second up to 99 for 99 seconds.
00 corresponds to a latched output.
The LED lights off during 1 second and an audible beep indicates
the validation of the time delay.
Time output relay 2
Access Level
Enter 2, then the time relay in second:
01 equal 1 second up to 99 for 99 seconds.
00 corresponds to a latched output.
The LED lights off during 1 second and an audible beep indicates
the validation of the time delay.
Enter 4 , then 01 for door 1 and controller activates relay 1
02 for door 2
activates relay 2
03 door 1 and 2
activates relay 1 2
The LED lights off during 1 second and an audible beep indicates
the validation of the access level.
Press # to exit from the programming mode. 2 beeps confirm that you returned
to reading mode.
4 beeps indicate a data computing error.
3

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]