HPSMU module specifications
Voltage range, resolution, and accuracy (high resolution ADC)
Voltage
range
Force
Measure
resolution resolution
Force accuracy¹
±2 V
100 µV
2 µV
±(0.018 % + 400 µV)
±20 V
1 mV
20 µV
±(0.018 % + 3 mV)
±40 V
2 mV
40 µV
±(0.018 % + 6 mV)
±100 V
5 mV 100 µV
±(0.018 % + 15 mV)
±200 V
10 mV 200 µV
±(0.018 % + 30 mV)
1. ± (% of read value + offset voltage V)
Measure accuracy¹
±(0.01 % + 140 µV)
±(0.01 % + 140 µV)
±(0.01 % + 1 mV)
±(0.012 % + 2.5 mV)
±(0.014 % + 2.8 mV)
Maximum current
1A
1A
500 mA
125 mA
50 mA
Current range, resolution, and accuracy (high resolution ADC)
Current
Force
Measure
Force accuracy²
Measure accuracy²
Maximum voltage
range
resolution resolution¹
±1 nA
50 fA
10 fA
±(0.1 %+300 fA+1 fA x Vo)
±(0.1 %+300 fA+1 fA x Vo)
200 V
±10 nA
500 fA
10 fA
±(0.1 %+3 pA+10 fA x Vo)
±(0.1 %+2.5 pA+10 fA x Vo)
200 V
±100 nA
5 pA 100 fA
±(0.05 %+30 pA+100 fA x Vo)
±(0.05 %+25 pA+100 fA x Vo)
200 V
±1 µA
50 pA
1 pA
±(0.05 %+300 pA+1 pA x Vo)
±(0.05 %+100 pA+1 pA x Vo)
200 V
±10 µA
500 pA
10 pA
±(0.05 %+3 nA+10 pA x Vo)
±(0.04 %+2 nA+10 pA x Vo)
200 V
±100 µA
5 nA 100 pA
±(0.035 %+15 nA+100 pA x Vo) ±(0.03 %+3 nA+100 pA x Vo)
200 V
±1 mA
50 nA
1 nA
±(0.04 %+150 nA+1 nA x Vo)
±(0.03 %+60 nA+1 nA x Vo)
200 V
±10 mA
500 nA
10 nA
±(0.04 %+1.5 nA+10 nA x Vo)
±(0.03 %+200 nA+10 nA x Vo)
200 V
±100 mA
5 µA 100 nA
±(0.045 %+15 µA+100 nA x Vo)
±(0.04 %+6 µA+100 nA x Vo)
³
±1 A
50 µA
1 µA
±(0.4 %+300 µA+1 µA x Vo)
±(0.4 %+150 µA+1 µA x Vo)
³
1. Specified measurement resolution is limited by fundamental noise limits.
2. ± (% of read value + offset current (fixed part determined by the output/measurement range + proportional part that is multiplied by Vo))
3. 200 V (Io ≤ 50 mA), 100 V (50 mA < Io ≤ 125 mA), 40 V (125 mA < Io ≤ 500 mA), 20 V (500 mA < Io ≤ 1 A), Io is the output current in Amps.
Voltage range, resolution, and accuracy (high speed ADC)
Voltage
range
Force
Measure
resolution resolution
Force accuracy¹
±2 V
100 µV
2 µV
±(0.018 % + 400 µV)
±20 V
1 mV
20 µV
±(0.018 % + 3 mV)
±40 V
2 mV
40 µV
±(0.018 % + 6 mV)
±100 V
5 mV 100 µV
±(0.018 % + 15 mV)
±200 V
10 mV 200 µV
±(0.018 % + 30 mV)
1. ± (% of read value + offset voltage V)
Measure accuracy¹
±(0.01 % + 700 µV)
±(0.01 % + 4 mV)
±(0.015 % + 8 mV)
±(0.02 % + 20 mV)
±(0.035 % + 40 mV)
Maximum current
1A
1A
500 mA
125 mA
50 mA
5