ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 5. Static Electrical Characteristics
Characteristics noted under conditions 4.75V V2 5.25V, 5.5V VSUP 18V, and -40°C TA 125°C. Typical values noted
reflect the approximate parameter mean at TA = 25°C under nominal conditions, unless otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
INPUT PIN (VSUP)
Supply Voltage
Nominal DC Voltage
Extended DC Voltage: Full Functionality(8)
Extended DC Voltage: Reduced Functionality(9)
Load Dump
Jump Start
VSUP
V
5.5
18
18
27
4.5
5.5
40
27
Supply Current in Standby Mode(10)
(IOUT at VDD = 40mA, CAN Recessive or Sleep Mode)
TA 25°C
ISUP(STDBY)
mA
42
45
Supply Current in Normal Mode(10)
(IOUT at VDD = 40mA, CAN Recessive or Sleep mode)
TA 25°C
ISUP(NORM)
mA
42
45
Supply Current in Sleep Mode(10)
(VDD and V2 OFF, CAN in Sleep Mode with CAN Wake-up Disabled(11))
ISUP(SLP-WD)
VSUP < 13.5V, Oscillator Running(12)
VSUP < 13.5V, Oscillator Not Running(13)
VSUP = 18V, Oscillator Running(12)
μA
85
105
53
80
110
140
Supply Current in Sleep Mode(10)
(V1 and V2 OFF, VSUP < 13.5V, Oscillator Not Running(13), CAN in Sleep
ISUP(SLP-WE)
μA
Mode with Wake-up Enabled)
TA = - 40°C
TA = 25°C
TA = 125°C
80
65
55
Supply Current in Stop Mode(10)
(IOUT at VDD < 2.0mA, VDD ON, CAN in Sleep Mode with Wake-up
Disabled(11))
VSUP < 13.5V, Oscillator Running(12)
VSUP < 13.5V, Oscillator Not Running(13)
VSUP = 18V, Oscillator Running(12)
ISUP(STOP-WD)
μA
160
80
160
100
210
Notes
8. All functions and modes available and operating: Watchdog, HS turn ON/turn OFF, CAN transceiver operating, L0:L3 inputs operating,
normal SPI operation. The 33742 may experience an over-temperature fault.
9. At VDD > 4.0V, RST HIGH if reset 2 selected via SPI. The logic HIGH level will be degraded but the 33742 is functional.
10. Current measured at the VSUP pin.
11. If CAN Module is Sleep-enabled for wake-up, an additional current (ICAN-SLEEP) must be added to specified value.
12. Oscillator running means one of the following function is active: Forced Wake-up or Cyclic Sense or Software Watchdog in Stop mode.
13. Oscillator not running means none of the following functions are active: Forced Wake-up and Cyclic Sense and Software Watchdog in
Stop mode.
Analog Integrated Circuit Device Data