SP8647
ELECTRICAL CHARACTERISTICS
Unless otherwise stated, the Electrical Characteristics are guaranteed over specified supply, frequency and temperature range
ECL OPERATION
Supply voltage, VCC = 0V, VEE = 25·2V 6 0·25V
Temperature, TAMB = 230°C to 170°C
Characteristic
Value
Symbol
Units
Min. Max.
Conditions
Notes
Maximum frequency (sinewave input)
fMAX
250
MHz Input = 400-800mV p-p
5
Minimum frequency (sinewave input)
fMIN
50 MHz Input = 400-800mV p-p
5
Power supply current
IEE
65
mA VEE = 25·2V
5
ECL output high voltage
VOH 20·85 20·7 V VEE = 25·2V (25°C)
ECL output low voltage
VOL
21·8 21·5
V VEE = 25·2V (25°C)
Clock and PE input high voltage
VINH 20·93
V VEE = 25·2V (25°C)
Clock and PE input low voltage
VINL
21·62 V VEE = 25·2V (25°C)
Clock to ECL output delay
tp
6
ns
6
Set-up time
ts
2·5
ns
3, 6
Release time
tr
3
ns
4, 6
TTL OPERATION
Supply voltage, VCC = 5V 6 0·25V, VEE = 0V
Temperature, TAMB = 230°C to 170°C
Characteristic
Symbol
Value
Min. Max.
Units
Conditions
Notes
Maximum frequency (sinewave input)
fMAX
250
MHz Input = 400-800mV p-p
5
Minimum frequency (sinewave input)
fMIN
50 MHz Input = 400-800mV p-p
5
Power supply current
IEE
65 mA
5
TTL output low voltage
VOL
0·5
V VCC = 5·25V, sink current = 8mA 5, 7
TTL output high voltage
VOH
3·5
V VCC = 5·0V
5, 7
Clock to TTL output high delay,1ve going
tPLH
15
ns
6
Clock to TTL output low delay,2ve going
tPHL
15
ns
6
Set-up time
ts
2·5
ns
3, 6
Release time
tr
3
ns
4, 6
NOTES
1. The temperature coefficients of VOH = 11·63mV/°C, VOL = 10·94mV/°C and of VIN = 11·22mV/°C.
2. The test configuration for dynamic testing is shown in Fig.6.
3. The set-up time ts is defined as the minimum time that can elapse between LH transition of control input and the next LH clock pulse transition
to ensure that the 410 mode is obtained.
4. The release time tr is defined as the minimum time that can elapse between HL transition of control input and the next LH clock pulse transition
to ensure that the 411 mode is obtained.
5. Tested at 25°C only.
6. Guaranteed but not tested.
7. The open collector output is not recommended for use at output frequencies above 15MHz. CLOAD < 5pF.
1200
1000
800
600
400
200
0
0
TAMB = 230°C TO 170°C
GUARANTEED
OPERATING
*
WINDOW
100
200
300
INPUT FREQUENCY (MHz)
Fig. 3 Typical input characteristic
* Tested as specified
in table of Electrical
Characteristics