10
MX806A
®
Figure 5: LMR Audio Processor Explanatory Block Diagram
5 Controlling Protocol
Control of the functions and levels within the MX806A LMR Audio processor is by a group of
Address/Commands and appended data instructions from the system microcontroller. The use of these
instructions is detailed in the following paragraphs and tables.
Command Assignment
Address/Command Binary
Command Data Table
HEX
MSB
LSB
General Reset
01
00000001
Control Command
10
00010000
+
1 byte
2
Mode Command
11
00010001
+
1 byte
3
Mod. Levels Set
12
00010010
+
2 bytes
4
Volume Set
13
00010011
+
1 byte
5
Table 3: C-BUS Address/Commands
In “C-BUS” protocol the MX806A is allocated Address/Command values 10H and 13H. C-BUS Command
Mode, Modulation and Volume assignments, and data requirements are given in Table 3 and illustrated in
Figure 5.
Commands and Data are only to be loaded in the group configurations detailed since the “C-BUS” interface
recognizes the first byte after Chip Select (logic “0”) as an Address/Command.
Function or Level control data, which is detailed in Table 4, Table 5, Table 6, and Table 7, is acted upon at
the end of the loaded instruction