Revision 0.3
MultiMediaCardTM
4. Product Specifications
4.1 Reliability and Durability
Temperature
Moisture and corrosion
ESD protection
Durability
Bending
Torque
Drop test
UV light exposure
Visual inspection
Shape and form
operation: -25°C / 85°C
storage: -40°C (168h) / 85°C (500h)
junction temperature: max. 95°C
operation: 25°C / 95% rel. humidity
stress: 40°C / 93% rel. hum./500h
salt water spray:
3% NaCl/35C; 24h acc. MIL STD 883 Method 1009
Contact Pads:
+/- 4kV, Human body model according to ANSI EOS/ESD-S5.1-1998
Non Contact Pads area:
+/-8kV (coupling plane discharge)
+/-15kV (air discharge)
Human body model according to IEC61000-4-2
10.000 mating cycles; test t.b.d.
t.b.d.
t.b.d.
1.5m free fall
UV: 200nm, 15Ws/cm² according to ISO 7816-1
no warpage; no mold skin; complete form; no cavities surface smoothness
sigma-0.1 mm/cm2 within contour; no cracks; no pollution (fat, oil dust, etc.)
Table 4-1 : Environmental Specification Summary
11
Sep.22.2005