Philips Semiconductors
Dual 4-channel analog multiplexer,
demultiplexer
Product specification
74HC4052; 74HCT4052
RECOMMENDED OPERATING CONDITIONS
SYMBOL
PARAMETER
VCC
supply voltage
VI
VS
Tamb
tr, tf
input voltage
switch voltage
operating ambient
temperature
input rise and fall times
CONDITIONS
see Figs 7 and 8
VCC − GND
VCC − VEE
see DC and AC
characteristics per
device
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
VCC = 10.0 V
74HC4052
74HCT4052
UNIT
MIN. TYP. MAX. MIN. TYP. MAX.
2.0 5.0
2.0 5.0
GND −
VEE −
−40 +25
−40 −
−
6.0
−
6.0
−
6.0
−
6.0
10.0 4.5 5.0
10.0 2.0 5.0
VCC GND −
VCC VEE −
+85 −40 +25
+125 −40 −
1000 −
6.0
500 −
6.0
400 −
6.0
250 −
6.0
5.5 V
10.0 V
VCC V
VCC V
+85 °C
+125 °C
500 ns
500 ns
500 ns
500 ns
handbook,1h2alfpage
VCC − GND
(V)
8
4
MNB044
operating area
0
0
4
8
12
VCC − VEE (V)
12
handbook, halfpage
VCC − GND
(V)
10
8
6
4
2
0
0
MNB045
operating area
4
8
12
VCC − VEE (V)
Fig.7 Guaranteed operating area as a function of
the supply voltages for 74HC4052.
Fig.8 Guaranteed operating area as a function of
the supply voltages for 74HCT4052.
2004 Nov 11
7