datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

NJU6624CFG1 데이터 시트보기 (PDF) - Japan Radio Corporation

부품명
상세내역
일치하는 목록
NJU6624CFG1 Datasheet PDF : 27 Pages
First Prev 21 22 23 24 25 26 27
NJU6624C
Note 4 : Apply to the OSC1, SCL, DATA, CS, RESET Terminals.
Note 5 : “Pull-up MOS Current 1” : Apply to the DATA Terminals.
“Pull-up MOS Current 2” and “Input Voltage 2” : Apply to the K0 to K3 Terminals.
Note 6 : Apply to the P0 to P3, REQ, DATA Terminals.
Note 7 : If the input level is medium, current consumption will increase due to the penetration current. Therefore,
the input level must be fixed to "H" or "L".
-Operating Current Measurement Circuit
5V
NJU6624
A
VDD
VSS
Note 8 : RCOM and RCOM are the resistance values between power supply terminals (VSS, VLCD2 or V1,V2,V4) and
each common terminal (COM1 to COM7/COMMK) and supply voltage (VSS, VLCD2 or V1,V2,V4) and each
segment terminal (SEG1 to SEG70) respectively, and measured when the current Id is flown on every
common and segment terminals at a same time.
Note 9 : Apply to the output voltage from each COM and SEG are less than +0.15V against the LCD driving
constant voltage (VDD, VLCD1) at no load condition.
Note 10: Apply to the SCL,CS,RESET Terminals.

Share Link: 