L9823
ELECTRICAL CHARACTERISTCS (continued)
Symbol
Parameter
Test Condition
Min. Typ. Max. Unit
IIN Input current
VIN = VDD
-10
10
µA
RIN Pullup resistance
(CSB, SI)
Pulldown resistance
(SFPD, Reset, SCLK)
50
250
kΩ
CIN Input capacitance
10
pF
Serial data outputs
VSOH High output level
ISO = -4mA
VDD -0.4
V
VSOL Low output level
ISO = 3,2mA
0.4
V
ISOL Tristate leakage current
CSB = high; 0V ≤ VSO ≤ VDD
-10
10
µA
CSO Output capacitance
fSO = 300kHz, 0V ≤ VSO ≤ VDD
20
pF
Outputs OUT 0 ... 7
IOUTL0 - 7 Leakage current
OUTx = OFF; VOUTx = 16V;
-10
10
µA
VDD ≤ VDD RES and / or Reset = Low
Tj ≤ 85°C
<1µA
VOUT Output clamp voltage
clamp
2mA ≤ IOUT clamp ≤ IOUT LIM
45
IOUT test = 20mA with correlation
60
V
RDSon On resistance OUT 0 ... 7
IOUT = 500mA;Tj = +150°C
Tj = +25°C
1
1.5
Ω
0.8 1.25
Ω
COUT Output capacitance
VOUT = 16V; f = 1MHz
300
pF
Outputs short circuit protection
ISCB Overcurrent shutoff threshold
SFPD = Low, VOUT ≥ VDG
0.5 1.6
2.5
A
IOUT LIM Short circuit current limitation
0.5 1.6
2.5
A
tdly SCB Short circuit shutdown delay
SFPD = Low, VOUT ≥ VDG
CSB = 50% to
IOUT ≤ 1/2 IOUT LIM
70
150 250
µs
Diagnostics
VDG Diagnostic threshold voltage
0.5·VDD 0.55·V 0.6·VDD V
DD
IOUT OL Open load detection sink current Vout = VDG
Output programmed OFF
30
60
100
µA
tdly SFPD Diagnostic detection filter time
SFPD = Low, VOUT ≥ VDG
CSB = 50% to
valid data at SO
70
150 250
µs
Outputs timing
tdon Turn ON delay
CSB = 50% to RL = 50Ω
VOUT = 0,9Vbat, Vbat = 16V
20
µs
5/12