datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

BR24T128FVJ-WE2_ 데이터 시트보기 (PDF) - ROHM Semiconductor

부품명
상세내역
일치하는 목록
BR24T128FVJ-WE2_ Datasheet PDF : 22 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
BR24T□□□□Series
Technical Note
I/O peripheral circuit
Pull up resistance of SDA terminal
SDA is NMOS open drain, so requires pull up resistance. As for this resistance value (RPU), select an appropriate value to
this resistance value from microcontroller VIL, IL, and VOL-IOL characteristics of this IC. If RPU is large, action frequency is
limited. The smaller the RPU, the larger the consumption current at action.
Maximum value of RPU
The maximum value of RPU is determined by the following factors.
SDA rise time to be determined by the capacitance (CBUS) of bus line of RPU and SDA should be tR or below.
And AC timing should be satisfied even when SDA rise time is late.
The bus electric potential A to be determined by input leak total (IL) of device connected to bus at output of 'H' to
SDA bus and RPU should sufficiently secure the input 'H' level (VIH) of microcontroller and EEPROM including
recommended noise margin 0.2Vcc.
VCCILRPU0.2 VCC VIH
RPU 0.8VCC VIH
IL
Ex.) VCC =3V IL=10µA VIH=0.7 VCC
from
RPU
0.8 3 0.7 3
10 106
300 [kΩ]
Microcontroller
RPU
A
BR24TXX
SDA terminal
IL
IL
Bus line
capacity
CBUS
Fig.52 I/O circuit diagram
Minimum value of RPU
The minimum value of RPU is determined by the following factors.
When IC outputs LOW, it should be satisfied that VOLMAX=0.4V and IOLMAX=3mA.
VCC VOL IOL
RPU
RPU VCC VOL
IOL
VOLMAX= should secure the input 'L' level (VIL) of microcontroller and EEPROM
including recommended noise margin 0.1Vcc.
VOLMAX VIL0.1 VCC
Ex.) VCC =3V, VOL=0.4V, IOL=3mA, microcontroller, EEPROM VIL=0.3Vcc
fromRPU
3 0.4
3 10 3
867[Ω]
And VOL=0.4V
VIL=0.3×3
=0.9V
Therefore, the condition is satisfied.
Pull up resistance of SCL terminal
When SCL control is made at CMOS output port, there is no need, but in the case there is timing where SCL becomes
'Hi-Z', add a pull up resistance. As for the pull up resistance, one of several kΩ ~ several ten kΩ is recommended in
consideration of drive performance of output port of microcontroller.
www.rohm.com
© 2011 ROHM Co., Ltd. All rights reserved.
14/21
2011.03 - Rev.A

Share Link: 