datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

74AHCT2G241-Q100 데이터 시트보기 (PDF) - Nexperia B.V. All rights reserved

부품명
상세내역
일치하는 목록
74AHCT2G241-Q100
NEXPERIA
Nexperia B.V. All rights reserved NEXPERIA
74AHCT2G241-Q100 Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Nexperia
74AHC2G241-Q100; 74AHCT2G241-Q100
Dual buffer/line driver; 3-state
Symbol Parameter Conditions
74AHCT2G241-Q100
tpd
propagation nA to nY; see Fig. 4
delay
VCC = 4.5 V to 5.5 V
CL = 15 pF
CL = 50 pF
ten
enable time 1OE to 1Y; see Fig. 5
VCC = 4.5 V to 5.5 V
CL = 15 pF
CL = 50 pF
2OE to 2Y; see Fig. 6
VCC = 4.5 V to 5.5 V
CL = 15 pF
CL = 50 pF
tdis
disable time 1OE to 1Y; see Fig. 5
VCC = 4.5 V to 5.5 V
CL = 15 pF
CL = 50 pF
2OE to 2Y; see Fig. 6
VCC = 4.5 V to 5.5 V
CL = 15 pF
CL = 50 pF
CPD
power
per buffer;
dissipation CL = 50 pF; fi = 1 MHz;
capacitance VI = GND to VCC
25 °C
-40 °C to +85 °C -40 °C to +125 °C Unit
Min Typ Max Min Max
Min
Max
[1]
[3]
- 3.4 5.5 1.0
6.5
1.0
7.0 ns
- 4.7 7.5 1.0
8.5
1.0
9.5 ns
[1]
[3]
- 3.9 5.1 1.0
6.0
1.0
6.5 ns
- 5.1 7.5 1.0
8.5
1.0
9.5 ns
[1]
[3]
- 3.4 5.6 1.0
6.3
1.0
6.5 ns
- 4.8 7.5 1.0
9.0
1.0
9.5 ns
[1]
[3]
- 4.5 6.8 1.0
8.0
1.0
8.5 ns
- 6.1 8.8 1.0
10.0
1.0
11.0 ns
[1]
[3]
- 4.0 6.8 1.0
8.0
1.0
8.5 ns
- 5.7 8.8 1.0
10.0
1.0
11.0 ns
[4] - 10 -
-
-
-
-
pF
[1] tpd is the same as tPLH and tPHL.
ten is the same as tPZL and tPZH.
tdis is the same as tPLZ and tPHZ.
[2] Typical values are measured at VCC = 3.3 V.
[3] Typical values are measured at VCC = 5.0 V.
[4] CPD is used to determine the dynamic power dissipation PD (μW).
PD = CPD x VCC2 x fi + ∑(CL x VCC2 x fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in Volts.
74AHC_AHCT2G241_Q100
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 16 January 2019
© Nexperia B.V. 2019. All rights reserved
7 / 14