Nexperia
74LVC1G18
1-of-2 non-inverting demultiplexer with 3-state deselected output
9,
*
9&&
92
'87
57
9(;7
5/
&/
5/
PQD
Test data is given in Table 10.
Definitions for test circuit:
RL = Load resistance.
CL = Load capacitance including jig and probe capacitance.
RT = Termination resistance should be equal to the output impedance Zo of the pulse generator.
VEXT = External voltage for measuring switching times.
Fig 5. Test circuit for measuring switching times
Table 10. Test data
VCC
1.65 V to 1.95 V
2.3 V to 2.7 V
2.7 V
Input
VI
VCC
VCC
2.7 V
3.0 V to 3.6 V
2.7 V
4.5 V to 5.5 V
VCC
tr = tf
2.0 ns
2.0 ns
2.5 ns
2.5 ns
2.5 ns
Load
CL
30 pF
30 pF
50 pF
50 pF
50 pF
RL
1 k
500
500
500
500
VEXT
tPLH, tPHL
open
open
open
open
open
tPZH, tPHZ
GND
GND
GND
GND
GND
tPZL, tPLZ
2 VCC
2 VCC
6V
6V
2 VCC
74LVC1G18
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 3 — 2 December 2016
© Nexperia B.V. 2017. All rights reserved
8 of 14