datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

74HCT4852PW 데이터 시트보기 (PDF) - Nexperia B.V. All rights reserved

부품명
상세내역
일치하는 목록
74HCT4852PW Datasheet PDF : 19 Pages
First Prev 11 12 13 14 15 16 17 18 19
Nexperia
74HC4852; 74HCT4852
Dual 4-channel analog multiplexer/demultiplexer with injection-current effect control
Symbol Parameter
74HCT4852
tpd
propagation
delay
ten
enable time
tdis
disable time
CPD
power
dissipation
capacitance
Conditions
25 °C
-40 °C to +85 °C -40 °C to +125 °C Unit
Min Typ Max Min
Max
Min
Max
nZ, nYn to nYn, nZ;
[1]
see Fig. 10
VCC = 4.5 V
1.6 3.5 11.5 1.1
12.5
Sn to nZ, nYn; see Fig. 11 [1]
VCC = 4.5 V
3.2 7.6 13 2.3
15
E to nZ, nYn; see Fig. 12 [2]
VCC = 4.5 V
4.2 8.3 25 3.0
30
E to nZ, nYn; see Fig. 12 [3]
VCC = 4.5 V
28.5 61.8 80 28.2
90
per channel; see Fig. 13 [4]
VCC = 5.0 V
- 47 -
-
-
1.1
1.6
3.0
28.0
-
13.5 ns
17 ns
35 ns
100 ns
- pF
[1] tpd is the same as tPLH and tPHL.
[2] ten is the same as tPZH and tPZL.
[3] tdis is the same as tPLZ and tPHZ.
[4] CPD is used to determine the dynamic power dissipation (PD in μW):
PD = CPD x VCC2 x fi + ∑{(CL + Csw) x VCC2 x fo} where:
fi = input frequency in MHz;
fo = output frequency in MHz;
∑{(CL + Csw) x VCC2 x fo} = sum of outputs;
CL = output load capacitance in pF;
Csw = switch capacitance in pF;
VCC = supply voltage in V.
11.1. Waveforms
VCC
nZ or nYn
input
GND
VCC
nYn or nZ
output
GND
0.5VCC
tPLH
0.5VCC
Fig. 10. Input (nZ, nYn) to output (nYn, nZ) propagation delays
VI
Sn input
GND
VCC
nYn or nZ
output
GND
VM
tPLH
VM
Measurement points are given in Table 10.
Fig. 11. Input (Sn) to output (nYn, nZ) propagation delays
tPHL
001aah578
tPHL
001aah579
74HC_HCT4852
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 4 — 28 April 2020
© Nexperia B.V. 2020. All rights reserved
11 / 19