datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

MB3773 데이터 시트보기 (PDF) - Cypress Semiconductor

부품명
상세내역
일치하는 목록
MB3773
Cypress
Cypress Semiconductor Cypress
MB3773 Datasheet PDF : 31 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MB3773
3. Functional Descriptions
Comp.S is comparator including hysteresis. it compare the reference voltage and the voltage of Vs, so that when the voltage of Vs
terminal falls below approximately 1.23 V, reset signal outputs.
Instantaneous breaks or drops in the power can be detected as abnormal conditions by the MB3773 within a 2 μs interval.
However because momentary breaks or drops of this duration do not cause problems in actual systems in some cases, a delayed
trigger function can be created by connecting capacitors to the Vs terminal.
Comp.O is comparator for turning on/off the output and, compare the voltage of the CT terminal and the threshold voltage. Because
the RESET/RESET outputs have built-in pull-up circuit, there is no need to connect to external pull-up resistor when connected to a
high impedance load such as CMOS logic IC.
(It corresponds to 500 kat Vcc = 5 V.) when the voltage of the CK terminal changes from the “high” level into the “Low” level, pulse
generator is sent to the watch-dog timer by generating the pulse momentarily at the time of drop from the threshold level.
When power-supply voltages fall more than detecting voltages, the watch-dog timer becomes an interdiction.
The Reference amplifier is an op-amp to output the reference voltage.
If the comparator is put up outside, two or more power-supply voltage monitor and overvoltage monitor can be done.
If it uses a comparator of the open-collector output, and the output of the comparator is connected with the Vs terminal of MB3773
without the pull-up resistor, it is possible to voltage monitor with reset-hold time.