datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

MGR2025CT 데이터 시트보기 (PDF) - Motorola => Freescale

부품명
상세내역
일치하는 목록
MGR2025CT
Motorola
Motorola => Freescale Motorola
MGR2025CT Datasheet PDF : 6 Pages
1 2 3 4 5 6
MOTOROLA
SEMICONDUCTOR TECHNICAL DATA
Order this document
by MGR2025CT/D
APdovwaencreMInafonramgaetiron
Gallium Arsenide Power Rectifier
. . . ideally suited for high frequency power supplies, free wheeling diodes, and as polarity
protection diodes, these state-of-the-art devices have the following features:
Planar Epitaxial Construction
Nitride Passivation for Stable Blocking Characteristics
Monolithic Dual Die Construction – May be Paralleled for
High Current Output (10A per leg or 20A per package)
Epoxy Meets UL94, VO @ 1/8
Hyperfast and Soft Reverse Recovery Over Specified Temperature
Range (15 ns)
Mechanical Characteristics
Case: Epoxy, Molded
Weight: 1.9 grams (approximately)
Finish: All External Surfaces Corrosion Resistant and Terminal Leads
are Readily Solderable
Lead Temperature for Soldering Purposes: 260°C Max. for 10 Seconds
Shipped 50 units per plastic tube
Marking: MGR2025CT
MAXIMUM RATINGS
Rating
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
DC Forward Current
(TC = 95°C)
Per Leg
Peak Repetitive Forward Current
(At Rated VR, Square Wave, 20 kHz, TC = 25°C)
Per Leg
Non–Repetitive Peak Surge Current
Per Package
(Surge applied at rated load conditions, halfwave, single phase, 60 Hz)
Operating Junction Temperature and Storage Temperature
THERMAL CHARACTERISTICS
Thermal Resistance – Junction to Case
Thermal Resistance – Junction to Ambient
ELECTRICAL CHARACTERISTICS
Per Leg
Per Leg
Maximum Instantaneous Forward Voltage (1), see Figure 2
(IF = 10 A)
(IF = 5 A)
Per Leg
Symbol
VRRM
VRWM
VR
IDC
IFRM
IFSM
TJ, Tstg
RθJC
RθJA
VF
Maximum Instantaneous Reverse Current, see Figure 4
Per Leg
IR
(VR = 250 V)
(VR = 125 V)
Typical Reverse Recovery Time (2)
(VR = 200 V, IF = 5 A, di/dt = 200 A/µs)
(VR = 200 V, IF = 10 A, di/dt = 200 A/µs)
Per Leg
trr
Typical Peak Reverse Recovery Current
(VR = 200 V, IF = 5 A, di/dt = 200 A/µs)
(VR = 200 V, IF = 10 A, di/dt = 200 A/µs)
Per Leg
Note: This data sheet contains advance information only and is subject to change without notice.
(1) Pulse Test: Pulse Width = 300 µs, Duty Cycle 2.0%.
(2) trr measured projecting from 25% of IRM to ground.
IRM
MGR2025CT
GALLIUM ARSENIDE
RECTIFIER
20 AMPERES
250 VOLTS
1
2, 4
3
4
1
2
3 CASE 221A-06
TO-220AB
Value
Unit
250
V
10
20
40
– 55 to 175
3.1
64
A
A
A
°C
°C/W
TJ=25°C TJ=125°C
V
2.2
2.5
1.5
1.6
TJ=25°C TJ=125°C
µA
25
440
2
125
TJ=25°C TJ=125°C
ns
11.8
12.0
12.2
12.2
TJ=25°C TJ=125°C
A
1.4
1.4
1.5
1.5
©MMoottoororolal,aInRc.F19D95evice Data