MITSUBISHI <INTELLIGENT POWER MODULES>
PM150RSD120
FLAT-BASE TYPE
INSULATED PACKAGE
BRAKE PART
Symbol
VCE(sat)
VFM
ICES
Parameter
Collector-Emitter
Saturation Voltage
FWDi Forward Voltage
Collector-Emitter
Cutoff Current
Test Condition
Min.
VD = 15V, IC = 50A
Tj = 25°C
—
VCIN = 0V, Pulsed
(Fig. 1) Tj = 125°C
—
IF = 50A
(Fig. 2) —
Tj = 25°C
—
VCE = VCES, VCIN = 15V
(Fig. 4) Tj = 125°C
—
Limits
Typ.
2.65
2.60
2.5
—
—
Max. Unit
3.30
3.25
V
3.5
V
1
10
mA
CONTROL PART
Symbol
Parameter
Test Condition
Limits
Min.
Typ.
Max. Unit
ID
Circuit Current
VD = 15V, VCIN = 15V
VN1-VNC
—
60
82
VXP1-VXPC
—
mA
15
20
Vth(on)
Vth(off)
Input ON Threshold Voltage Applied between : UP-VUPC, VP-VVPC, WP-VWPC
Input OFF Threshold Voltage
UN • VN • WN • Br-VNC
1.2
1.5
1.8
V
1.7
2.0
2.3
Inverter part
Tj = 25°C
282
410
—
OC
Over Current Trip Level
VD = 15V
(Fig. 5,6) Tj = 125°C
200
—
Break part
–20 ≤ Tj ≤ 125°C, VD = 15V
75
—
(Fig. 5,6)
—
A
—
SC
Short Circuit Trip Level
Inverter part
—
540
—
A
Brake part
—
144
—
toff(OC) Over Current Delay Time
(Fig. 5,6) —
10
—
µs
OT
Over Temperature Protection Base-plate
Trip level
OTr
Temperature detection, VD = 15V
Reset level
111
118
125
°C
—
100
—
UV
Supply Circuit Under-Voltage
UVr
Protection
–20 ≤ Tj ≤ 125°C
Trip level
Reset level
11.5
12.0 12.5
V
—
12.5
—
IFO(H)
IFO(L)
Fault Output Current
VD = 15V, VFO = 15V
—
(Note-3)
—
—
0.01
mA
10
15
Minimum Fault Output Pulse
tFO
Width
VD = 15V
(Note-3) 1.0
1.8
—
ms
(Note-3) Fault output is given only when the internal OC, SC, OT & UV protection.
Fault output of OC, SC and UV protection operate by upper and lower arms.
Fault output of OT protection operate by lower arm.
Fault output of OC, SC protection given pulse.
Fault output of OT, UV protection given pulse while over level.
MECHANICAL RATINGS AND CHARACTERISTICS
Symbol
—
—
—
Parameter
Mounting torque
Mounting torque
Weight
Main terminal
Mounting part
Test Condition
—
Limits
Min.
Typ.
Unit
Max.
screw : M5
2.5
3.0
3.5 N • m
screw : M5
2.5
3.0
3.5 N • m
—
920
—
g
RECOMMENDED CONDITIONS FOR USE
Symbol
Parameter
VCC
Supply Voltage
VD
Control Supply Voltage
VCIN(on)
VCIN(off)
Input ON Voltage
Input OFF Voltage
fPWM
PWM Input Frequency
tdead
Arm Shoot-through
Blocking Time
Test Condition
Recommended value
Unit
Applied across P-N terminals
≤ 800
V
Applied between : VUP1-VUPC, VVP1-VVPC
VWP1-VWPC, VN1-VNC
(Note-4)
15 ± 1.5
V
Applied between : UP-VUPC, VP-VVPC, WP-VWPC
UN • VN • WN • Br-VNC
≤ 0.8
≥ 4.0
V
Using Application Circuit input signal of IPM, 3φ
sinusoidal PWM VVVF inverter
(Fig. 8)
≤ 20
kHz
For IPM’s each input signals
(Fig. 7)
≥ 3.0
µs
(Note-4) Allowable Ripple rating of Control Voltage : dv/dt ≤ ±5V/µs, 2Vp-p
Jul. 2005