PERFORMANCE DATA*
LBA126
LBA126
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C)
IF = 5mADC
35
30
25
20
15
10
5
0
1.17 1.19 1.21 1.23 1.25
LED Forward Voltage Drop (V)
LBA126 - Form A
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
35
30
25
20
15
10
5
0
305 315 325 335 345 355 365
Blocking Voltage (V)
LBA126 - Form B
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
25
20
15
10
5
0
0.45 0.63 0.81 0.99 1.17 1.35 1.53
LED Current (mA)
LBA126 - Form A
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
25
20
15
10
5
0
0.625 0.875 1.125 1.375 1.625 1.875 2.125
Turn-On (ms)
LBA126 - Form A
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
35
30
25
20
15
10
5
0
6.5
7.5
8.5
9.5
10.5
On-Resistance ()
LBA126 - Form B
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
35
30
25
20
15
10
5
0
291.25 293.75 296.25 298.75 301.25 303.75
Blocking Voltage (V)
LBA126 - Form A
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
25
20
15
10
5
0
0.15
0.45 0.75 1.05 1.35 1.65 1.95
LED Current (mA)
LBA126 - Form B
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
30
25
20
15
10
5
0
0.30 0.42 0.54 0.66 0.78 0.90 1.02
Turn-On (ms)
LBA126 - Form B
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
35
30
25
20
15
10
5
0
10.4 10.8 11.2 11.6 12.0 12.4
On-Resistance ()
LBA126 - Form A
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
25
20
15
10
5
0
0.3 0.5 0.7 0.9 1.1 1.3 1.5
LED Current (mA)
LBA126 - Form B
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
40
35
30
25
20
15
10
5
0
0.45 0.63 0.81 0.99 1.17 1.35 1.53
LED Current (mA)
LBA126 - Form A
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
25
20
15
10
5
0
0.335 0.525 0.715 0.905 1.095 1.285 1.475
Turn-Off (ms)
The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact