ASDX Series A-grade
Signal conditioned high precision pressure transducers
PRESSURE RANGES SPECIFICATIONS
(VS = 5.0 VDC, TA = 25°C)
Part number
ASDX015A24R-A
ASDX030A24R-A
ASDX100A24R-A
ASDX001G24R-A / D44R-A
ASDX005G24R-A / D44R-A
ASDX015G24R-A / D44R-A
ASDX030G24R-A / D44R-A
ASDX100G24R-A / D44R-A
ASDX001D44D-A
ASDX005D44D-A
ASDX015D44D-A
Pressure range Burst pressure1 Sensitivity (typ.)
0 to 15
30
0.27
0 to 30 psi(a)
60
psi(a)
0.13
0 to 100
150
0.04
0 to 1
5
4.00
0 to 5
20
0.80
0 to 15
30
0.27
V/psi
0 to 30
60
0.13
psi(g,d)
psi(g,d)
0 to 100
150
0.04
0 to ±1
5
2.00
0 to ±5
20
0.40
0 to ±15
30
0.13
Specification notes:
1. If maximum burst pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die
may fracture.
2. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified
pressure. Span is ratiometric to the supply voltage.
3. Total accuracy is the combined error of offset and span calibration, linearity, pressure hysteresis and temperature
effects. Linearity is the measured deviation based on a straight line.
Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and
decreasing pressure. Calibration errors include the deviation of offset and full scale from nominal values.
4. Delay time between sampling and signal change at the output.
5. The smallest change in the output voltage, given any change in pressure.
February 2009 / 609
2/5
www.sensortechnics.com

Share Link: 