Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM75CSA120
Intellimod™ Module
Three Phase IGBT Inverter Output
75 Amperes/1200 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
IGBT Inverter Sector
Collector Cutoff Current
Diode Forward Voltage
Collector-Emitter Saturation Voltage
ICEX
VFM
VCE(sat)
Inductive Load Switching Times
Thermal Characteristics
Characteristic
Junction to Case Thermal Resistance
Contact Thermal Resistance
ton
trr
tC(on)
toff
tC(off)
Symbol
Rth(j-c)Q
Rth(j-c)D
Rth(c-f)
VCE = VCEX, Tj = 25°C
—
VCE = VCEX, Tj = 125°C
—
-IC = 75A, VD = 15V, VCIN = 0V
—
VD = 15V, VCIN = 15V, IC = 75A
—
VD = 15V, VCIN = 15V, IC = 75A,
—
Tj = 125°C
0.5
VD = 15V, VCIN = 0 ~ 15V
—
VCC = 600V, IC = 75A
—
Tj = 125°C
—
—
Condition
Min.
Each IGBT
—
Each FWDi
—
Case to Fin Per Module,
—
Thermal Grease Applied
Recommended Conditions for Use
Characteristic
Symbol
Supply Voltage
VCC
VD
Input ON Voltage
Input OFF Voltage
PWM nput Frequency
Minimum Dead Time
VCIN(on)
VCIN(off)
fPWM
tDEAD
Condition
Applied across P-N Terminals
Applied between VUP1-VUPC,
VN1-VNC, VVP1-VVPC, VWP1-VWPC
Applied between
UP, VP, WP, UN, VN, WN
Using Application Circuit
Input Signal
Typ. Max. Units
—
1.0
mA
—
10
mA
2.5
3.5
Volts
2.5
3.5
Volts
2.2
3.2
Volts
1.0
2.5
µS
0.15
0.3
µS
0.4
1.0
µS
2.0
3.0
µS
0.7
1.2
µS
Typ. Max. Units
—
0.25 °C/Watt
—
0.51 °C/Watt
—
0.027 °C/Watt
Value
0 ~ 800
15 ± 1.5
Units
Volts
Volts
0 ~ 0.8
4.0 ~ VD
5 ~ 20
≥ 2.5
Volts
Volts
kHz
µS
514