datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

PCF7936AS 데이터 시트보기 (PDF) - NXP Semiconductors.

부품명
상세내역
일치하는 목록
PCF7936AS
NXP
NXP Semiconductors. NXP
PCF7936AS Datasheet PDF : 33 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
NXP Semiconductors
Security Transponder (HITAG2)
Product Specification
PCF7936AS
Error
LF Field
Power On Reset
READ ONLY
time-out (tWAIT,SA)
&
Read Only = enabled
WAIT
START_AUTH
READ_PAGE
READ_PAGE_INV
WRITE_PAGE
AUTHORIZED
HALT
HALT
Figure 7. Transponder State Diagram
7.2 Transponder State Diagram
Device operation is controlled by commands issued from
the basestation, see Figure 7.
After a LF Field Power-On Reset condition the circuitry is
reset and the transponder is initialized, which causes the
device to enter the WAIT state.
If one of the Read Only modes is enabled, the device will
enter READ ONLY state after the specified time-out
(tWAIT,SA), if no command is being issued.
To authenticate the transponder and to access the
Transponder Memory for read and write the AUTHORIZED
state has to be entered, by means of a START_AUTH
command and successful completion of the authentication
sequence. Subsequent memory read and write operations
may be executed.
Operation of the transponder commands depend on the
device configuration (Password or Cipher Mode).
If the device is forced into HALT state, by means of the
HALT command, the transponder circuitry is muted.
A violation of the command sequence coding or command
timing in any state causes an error condition, which causes
the device to enter WAIT state and to reset the time-out
(tWAIT,SA).
7.2.1 WAIT State
In WAIT state general memory access is denied.
Commands may be issued to start device authentication, in
order to enter the AUTHORIZED state, see Table 2.
Table 2. Command Set in WAIT State
NAME
Reserved 1)
Reserved 1)
Reserved 1)
Reserved 1)
Reserved 1)
START_AUTH
COMMAND, CMD
CM4 CM3 CM2 CM1 CM0
0XXXX
X0XXX
XX1XX
XXX1X
XXXX1
1
1
0
0
0
Note
1. This command is reserved for future use and subject to
change without notice. The actual implementation
causes the device to generate an error condition and to
enter the WAIT state, if this command is being issued.
Upon entering the WAIT state the time-out (tWAIT,SA) is
reset. In case tWAIT,SA is allowed to time-out, the device
enters READ ONLY state, if one of the Read Only modes is
enabled. In case a START_AUTH command is issued,
device authentication is triggered and the READ ONLY
state is not entered. At least the first two bits of
START_AUTH need to be recognized by the device within
the time-out period specified by tWAIT,SA.
2010 May 04
11
CONFIDENTIAL

Share Link: 