DYNAMIC ELECTRICAL CHARACTERISTICS
Characteristics noted under conditions of 3.1 V VDD 5.25 V, 8.0 V VPWR 16 V, -40°C TC 125°C, unless otherwise noted.
Where applicable, typical values reflect the parameter’s approximate average value with VPWR = 13 V, TA = 25°C.
Characteristic
Symbol
Min
Typ
Max
Unit
SWITCH INPUT
Pulse Wetting Current Time
t pulse (on)
15
16
20
ms
Interrupt Delay Time
Normal Mode
t int-dly
µs
5.0
16
Sleep Mode Switch Scan Time
Calibrated Scan Timer Accuracy
Sleep Mode
t scan
100
200
300
µs
tscan timer
%
10
Calibrated Interrupt Timer Accuracy
Sleep Mode
tint timer
%
10
DIGITAL INTERFACE TIMING (Note 12)
Required Low State Duration on VPWR for Reset (Note 13)
VPWR 0.2 V
Falling Edge of CS to Rising Edge of SCLK
Required Setup Time
t RESET
t lead
100
µs
10
ns
Falling Edge of SCLK to Rising Edge of CS
Required Setup Time
t lag
ns
50
SI to Falling Edge of SCLK
Required Setup Time
t SI (su)
16
ns
Falling Edge of SCLK to SI
Required Hold Time
t SI (hold)
20
ns
SI, CS, SCLK Signal Rise Time (Note 14)
t r (SI)
5.0
ns
SI, CS, SCLK Signal Fall Time (Note 14)
t f(SI)
5.0
ns
Time from Falling Edge of CS to SO Low Impedance (Note 15)
t SO (en)
55
ns
Time from Rising Edge of CS to SO High Impedance (Note 16)
t SO (dis)
55
ns
Time from Rising Edge of SCLK to SO Data Valid (Note 17)
t valid
25
55
ns
Notes
12. These parameters are guaranteed by design. Production test equipment uses 4.16 MHz, 5.0 V SPI interface.
13. This parameter is guaranteed by design but not production tested.
14. Rise and Fall time of incoming SI, CS, and SCLK signals suggested for design consideration to prevent the occurrence of double pulsing.
15. Time required for valid output status data to be available on SO pin.
16. Time required for output states data to be terminated at SO pin.
17. Time required to obtain valid data out from SO following the rise of SCLK with 200 pF load.