datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

PM75CVA120 데이터 시트보기 (PDF) - Powerex

부품명
상세내역
일치하는 목록
PM75CVA120 Datasheet PDF : 6 Pages
1 2 3 4 5 6
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM75CVA120
Intellimod™ Module
Three Phase IGBT Inverter Output
75 Amperes/1200 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Control Sector
Short Circuit Trip Level
Short Circuit Current Delay Time
Over Temperature Protection
SC
toff(SC)
OT
-20°C Tj 125°C, VD = 15V
VD = 15V
Trip Level
105
10
100
110
(VD = 15V, Lower Arm)
OTr
Supply Circuit Under Voltage Protection
UV
Reset Level
Trip Level
85
95
11.5 12.0
(-20°C Tj 125°C)
UVr
Reset Level
Circuit Current
ID
VD = 15V, VCIN = 15V, VN1-VNC
VD = 15V, VCIN = 15V, VXP1-VXPC
Input ON Threshold Voltage
VCIN(on)
Applied between UP-VUPC, VP-VVPC, 1.2
Input OFF Threshold Voltage
VCIN(off)
WP-VWPC, UN, VN, WN-VNC
1.7
Fault Output Current
IFO(H)
VD = 15V, VFO = 15V*
IFO(L)
VD = 15V, VFO = 15V*
Minimum Fault Output Pulse Width
tFO
VD = 15V*
1.0
* Fault output is given only when the internal SC, OT, and UV protections circuits of either an upper-arm or a lower-arm device operate to protect it.
12.5
40
13
1.5
2.0
10
1.8
Max. Units
— Amperes
µS
120
°C
105
°C
12.5 Volts
Volts
55
mA
18
mA
1.8
Volts
2.3
Volts
0.01
mA
15
mA
mS
427

Share Link: 