datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

M24M01-VLA6P 데이터 시트보기 (PDF) - STMicroelectronics

부품명
상세내역
일치하는 목록
M24M01-VLA6P
ST-Microelectronics
STMicroelectronics ST-Microelectronics
M24M01-VLA6P Datasheet PDF : 21 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
M24M01
SUMMARY DESCRIPTION
The M24M01 is a 1 Mbit (131,072 x 8) electrically
erasable programmable memory (EEPROM) ac-
cessed by an I2C-compatible bus.
Figure 2. Logic Diagram
VCC
following the bus master’s 8-bit transmission.
When data is read by the bus master, the bus
master acknowledges the receipt of the data byte
in the same way. Data transfers are terminated by
a Stop condition after an Ack for Write, and after a
NoAck for Read.
Figure 3. LGA Connections
2
E1-E2
SCL
WC
M24M01
VSS
SDA
AI04048B
Table 1. Signal Names
E1, E2
Chip Enable
SDA
Serial Data
SCL
Serial Clock
WC
Write Control
VCC
VSS
Supply Voltage
Ground
I2C uses a two wire serial interface, comprising a
bi-directional data line and a clock line. The devic-
es carry a built-in 4-bit Device Type Identifier code
(1010) in accordance with the I2C bus definition.
The device behaves as a slave in the I2C protocol,
with all memory operations synchronized by the
serial clock. Read and Write operations are initiat-
ed by a Start condition, generated by the bus mas-
ter. The Start condition is followed by a Device
Select Code and RW bit (as described in Table 2),
terminated by an acknowledge bit.
When writing data to the memory, the device in-
serts an acknowledge bit during the 9th bit time,
DU
E1
E2
VSS
M24M01
1
8
2
7
3
6
4
5
VCC
WC
SCL
SDA
AI04051C
Note: 1. DU = Don’t Use (should be left unconnected, or tied to
VSS)
Power On Reset: VCC Lock-Out Write Protect
In order to prevent data corruption and inadvertent
Write operations during Power-up, a Power On
Reset (POR) circuit is included. At Power-up, the
internal reset is held active until VCC has reached
the POR threshold value, and all operations are
disabled – the device will not respond to any com-
mand. In the same way, when VCC drops from the
operating voltage, below the POR threshold value,
all operations are disabled and the device will not
respond to any command. A stable and valid VCC
must be applied before applying any logic signal.
When the power supply is turned on, VCC rises
from VSS to VCC(min), passing through a value Vth
in between. The device ignores all instructions un-
til a time delay of tPU has elapsed after the mo-
ment that VCC rises above the Vth threshold.
However, the correct operation of the device is not
guaranteed if, by this time, VCC is still below
VCC(min).No instructions should be sent until the
later of:
– tPU after VCC passed the Vth threshold
– VCC passed the VCC(min) level
These values are specified in Table 9.
4/21

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]