RM6203
ELECTRICAL CHARACTERISTICS
The specifications are applied at T=25, VCC=5.5-7.5V, Ct=680PF, RS=1Ω, unless otherwise noted.(Note 2)(continued)
Re-enabling voltage
Over-Voltage Limiting
Threshold
3.8
V
9.5
10
10.5
V
Note1: Stresses beyond those listed under Absolute Maximum
Ratings may cause permanent damage to the device.
Exposure to any Absolute Maximum Rating condition for
Note2: TheRM6203 is guaranteed to meet performance
specifications from 0to 70. Specifications over the -40
to 85operating temperature range are assured by design,
extended periods may affect device reliability and lifetime.
characterization and correlation with statistical process
controls.
BLOCK DIAGRAM
OPERATION (Refer to Block Diagram)
In the enabling stage, when power is on, VR is closed; the
pull-up current source FB is closed; OE inputs enabling current
from power tube to VCC; OB controls the base current of the
power tube, limits the collector current of the power tube (i.e.
RM6203 initiates the reception current), so as to ensure the
safety of the power tube; when VCC voltage raises up to 7.8 V,
the enabling stage ends and it goes into the normal stage.
In the normal stage, VCC voltage should be maintained at
4.8V to 9.0V, VR outputs 2.5V reference; FB pull-up current
source is opened; the oscillator output OSC1 decides the
maximum duty ratio, output OSC2 tries to trigger the power
into open period, and the screened power tube turns on the
current peak; if FB is below 1.8V (approximately between 1.2V
and 1.8V), the oscillator period will then be increased, the
smaller the FB is, the wider the oscillator period will be, until
the stop of the oscillator (this feature will lower the stand-by
power consumption of the switch power source); if the external
feedback intends to make VCC higher than 10V, the internal
circuit feedback to FB will stabilize VCC at 9.8V (with this
feature, the internal circuit rather than the external feedback
circuit will be used to stabilize the output voltage, but the
stabilizing accuracy may be low); in the open period, OB
supplies base current to power tube, OE pulls down the emitter
of the power tube to IS, and the OB uses the slope current
driving (i.e. the OB open current is the function of IS, when IS
= 0V, OB open current is approximately 40mA, then the OB
4
www.reactor-micro.com