DATA SHEET • SKY13381-374LF DPDT SWITCH
Table 1. SKY13381-374LF Signal Descriptions
Pin #
Name
Description
Pin #
1
ANT2
Antenna 2 RF port. Must be DC-blocked for
4
proper operation.
2
V2
DC control voltage 2
5
3
RX
Receive RF port. Must be DC-blocked for
6
proper operation.
Note: Exposed backside ground pad must be properly grounded through a low impedance path.
Name
TX
V1
ANT1
Description
Transmit RF port. Must be DC-blocked for
proper operation.
DC control voltage 1
Antenna 1 RF port. Must be DC-blocked for
proper operation.
Table 2. SKY13381-374LF Absolute Maximum Ratings
Parameter
Symbol
Minimum
Maximum
Units
Control voltage
V1, V2
6
V
RF input power
PIN
+39
dBm
Storage temperature
TSTG
40
+125
°C
Operating temperature
TOP
40
+85
°C
Note: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. SKY13381-374LF Recommended Operating Conditions
Parameter
Symbol
Minimum
Typical
Maximum
Units
Frequency
f
0.1
6.0
GHz
Control voltage
V1, V2
1.8
3.0
5.0
V
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY13381-374LF are
provided in Table 2. The recommended operating conditions are
specified in Table 3 and electrical specifications are provided in
Table 4.
Typical performance characteristics of the SKY13381-374LF are
illustrated in Figures 3 through 5.
The state of the SKY13381-374LF is determined by the logic
provided in Table 5.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com