!Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
1 GMD Series Specifications and Test Methods (1)
C02E.pdf
Nov.27,2017
No
Item
Specification
1 Rated Voltage
2 Appearance
3 Dimension
4 Voltage Proof
Shown in Rated value.
No defects or abnormalities.
Within the specified dimensions.
No defects or abnormalities.
5 Insulation Resistance (I.R.)
C <= 0.047µF: More than 10000MΩ
C > 0.047µF: More than 500Ω F
C: Nominal Capacitance
6 Capacitance
7 Dissipation Factor (D.F.)
No Bias
Shown in Rated value.
W.V.: 25Vdc min.: 0.025max.
W.V.: 16/10Vdc: 0.035max.
B1, B3: Within ±10% (-25 to +85°C)
R1, R7: Within ±15% (-55 to +125°C)
R6: Within ±15% (-55 to +85°C)
Temperature
8 Characteristics
of Capacitance 50% of
the Rated
Voltage
B1: Within +10/-30%
R1: Within +15/-40%
Bond
Adhesive
Strength
9 Strength of
Termination
Die Shear
Strength
Pull force: 0.03N min.
Die Shear force: 2N min.
10
Vibration
*
Appearance No defects or abnormalities.
Capacitance Within the specified initial value.
D.F.
Within the specified initial value.
Appearance No defects or abnormalities.
Capacitance
Change
Within ±7.5%
Temperature D.F.
11
Sudden
Change
I.R.
*
Within the specified initial value.
Within the specified initial value.
Voltage
Proof
No defects.
Test Method (Ref. Standard: JIS C 5101, IEC60384)
The rated voltage is defined as the maximum voltage which
may be applied continuously to the capacitor.
When AC voltage is superimposed on DC voltage, VP-P or VO-P,
whichever is larger, should be maintained within the rated
voltage range.
Visual inspection.
Using Measuring instrument of dimension.
Measurement Point: Between the terminations
Test Voltage: 250% of the rated voltage
Applied Time: 1 to 5s
Charge/discharge current: 50mA max.
Measurement Point: Between the terminations
Measurement Voltage: DC Rated Voltage
Charging Time: 2min
Charge/discharge current: 50mA max.
Measurement Temperature: Room Temperature
Measurement Temperature: Room Temperature
Measurement Frequency: 1.0±0.1kHz
Measurement Voltage: 1.0±0.2Vrms
The capacitance change should be measured a er 5 minutes at
each specified temp. stage.
In case of applying voltage, the capacitance change should be
measured a er 1 minute with applying voltage in equilibration of
each temp. stage.
Capacitance value as a reference is the value in step 3.
Step
1
2
3
4
5
6
7
8
Temperature (°C)
Reference Temp. ±2
Min.Operating Temp. ±3
Reference Temp. ±2
Max.Operating Temp. ±3
Reference Temp. ±2
Min.Operating Temp. ±3
Reference Temp. ±2
Max.Operating Temp. ±3
Applying Voltage (VDC)
No bias
50% of
the rated voltage
(For B1, R1)
Initial measurement
Perform a heat treatment at 150+0/-10°C for 1h and then let
sit for 24±2h at room temperature, then measure.
MIL-STD-883 Method 2011 Condition D
Mount the capacitor on a gold metalized alumina substrate with
Au-20Sn and bond a ø25µm (ø0.001 inch) gold wire to the
capacitor terminal using an ultrasonic ball bond. Then, pull wire.
MIL-STD-883 Method 2019
Mount the capacitor on a gold metalized alumina substrate with
Au-20Sn. Apply the force parallel to the substrate.
Kind of Vibration: A simple harmonic motion
10Hz to 55Hz to 10Hz (1min)
Total amplitude: 1.5mm
This motion should be applied for a period of 2h in each 3
mutually perpendicular directions (total of 6h).
Perform the five cycles according to the four heat treatments
shown in the following table.
Step
Temp. (°C)
Time (min)
1 Min. Operating Temp. +0/-3 30±3
2
Room Temp.
2 to 3
3 Max. Operating Temp. +3/-0 30±3
4
Room Temp.
2 to 3
Exposure Time: 24±2h
Initial measurement
Perform a heat treatment at 150+0/-10°C for 1h and then
let sit for 24±2h at room temperature, then measure.
Continued on the following page.
259