Camera Features (not shown)
YC Out (SVHS Video) Output Connector- When using a high resolution monitor, connect one end of the
SVHS cable into this receptacle and the other end to the “SVHS In” receptacle located in the
rear of the monitor.
• Power Supply Connector - Insert the 12V connector extending from the rear of the BGA/CSP-3500
Main Unit into this receptacle.
Video Out Connector - If using a monitor without SVHS capability, connect one end of the video cable
to this female BNC receptacle and the other to the monitor’s “Video In” connector
IV. SET-UP PROCEDURES
Prior to performing initial set-up, unpack all accessories from shipping containers. Check that your
BGA/CSP-3500 has arrived complete by verifying all of the accessories listed in Section II have been
included. After all components are located, begin setup.
Placement Section
IMPORTANT: There is a transportation screw located on the bottom of the placement arm and on the tool-
ing plate/component slide to stop these parts from moving during transportation. Completely loosen or
remove these screws prior to operation to allow these parts to move freely without any restrictions.
When setting up this equipment, be sure to arrange it in a position that allows the user to operate this
machine in a comfortable, well-spaced environment.
1. Remove the BGA/CSP-3500 Main Unit, Control Unit, Camera, 20” High-Resolution Monitor (optional)
and all accessories from there shipping containers.
2. Mount the camera to the lens by rotating the camera clockwise so that it fully screws onto the top of
the lens assembly.
3. Connect the black cable extending from the rear of the BGA/CSP-3500 base unit to the connector
marked “12VDC IN” located on the rear of the camera.
4. Connect one end of the appropriate video cable (SVHS or BNC) to the appropriate video output
connector (“Y/C Out” for SVHS or “Video Out” for standard video) on the rear of the camera. Connect
the other end to the correct input on the rear of the monitor.
5. Connect the 5 pin female connector extending from the FS-24 footswitch to the corresponding 5 pin
male connector located on the rear of the BGA/CSP-3500 Main Unit.
6. Select the medium vacuum pipette and attach it to the vacuum shaft of the Placement Head.
IMPORTANT: Every BGA/CSP-3500 Rework System has been factory calibrated.
Recalibration may be required after initial setup due to shipping or rough handling. Verifying calibration is
strongly recommended prior to initial use. This procedure is thoroughly discussed later in the manual in the
section titled “Calibration Proceedure.”
Reflow Section
IMPORTANT: Prior to initial setup of your BGA/CSP-3500, please remove the transportation screw located on
the bottom of the BGA-3500 Series Control Unit. Tilt the unit on its side and remove the screw with a
Phillips-head screwdriver.
10
BGA-3500 Series Manual 5/01