datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

RXM-418-KH3 데이터 시트보기 (PDF) - Unspecified

부품명
상세내역
일치하는 목록
RXM-418-KH3
ETC
Unspecified ETC
RXM-418-KH3 Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Pin Assignments
Pin Descriptions
1 LADJ/GND
2 D0
3 D1
4 GND
5 VCC
6 TE
7 D2
8 D3
9 D4
10 D5
11 D6
12 D7
25 26
ANT 24
GND 23
A9 22
A8 21
A7 20
A6 19
A5 18
A4 17
A3 16
A2 15
A1 14
A0 13
27
Figure 13: KH3 Series Transmitter Pin Assignments (Top View)
Pin Descriptions
Pin Number Name I/O Description
Level Adjust. This line adjusts the output power level
1
GND /
LADJ
of the transmitter. Connecting to GND gives the
highest output, while placing a resistor to GND lowers
the output level.
2, 3, 7, 8, 9,
10, 11,12
D0 to D1
Data Input Lines. When TE goes high, the module
encodes the state of these lines for transmission.
I Upon receipt of a valid transmission, the receiver /
decoder replicates these lines on its output lines.
These lines are pulled to GND internally.
4, 23
GND — Analog Ground
5
VCC
— Supply Voltage
Transmit Enable Line. When this line goes high, the
6
TE
I/O
module encodes the states of the address and data
lines into a packet and transmits the packet three
times.
13, 14, 15,
16, 17, 18,
19, 20, 21, 22
24
A0 to A9
ANT
Address Lines. The state of these lines must match
I
the state of the receiver’s address lines in order for a
transmission to be accepted. These lines are pulled
to VCC internally.
— 50-ohm RF Output
Data Line Configuration. Determines whether a low
25
D_CFG
I/O
on a data line is interpreted as a zero bit or an open
bit. See the Input Type Selection section. This line is
pulled to GND internally.
26, 27
A_CFG0 /
A_CFG1
Address Configuration. These lines determine the
address bit type interpretation. See the Input Type
Selection section. A_CFG0 is pulled to GND and
A_CFG1 is pulled to VCC internally.
Figure 14: KH3 Series Transmitter Pin Descriptions
8
Module Description
The KH3 Series transmitter / encoder module combines a
high-performance Surface Acoustic Wave (SAW) based transmitter with an
on-board remote control encoder. When combined with a Linx KH3 Series
receiver / decoder, a highly reliable RF link capable of transferring control or
command data over line-of-sight distances of up to 3,000 feet is formed.
The module accepts up to 8 parallel inputs, such as switches or contact
closures, and provides ten address lines for creating unique transmitter
/ receiver relationships. The KH3’s compact surface-mount package
integrates easily into existing designs and is friendly to hand production or
automated assembly.
50Ω RF OUT
(ANT)
Keyed Output
SAW
Oscillator
Address Inputs
TX Enable
A0-A9
D_CFG
D_CFG0
D_CFG1
Output Isolation RF Amplifier
& Filter
RF STAGE
Data Out
ENCODER STAGE
Parallel
Inputs
D0-D7
Figure 15: KH3 Series Transmitter Block Diagram
9

Share Link: 