Data Sheet
AD633
SPECIFICATIONS
TA = 25°C, VS = ±15 V, RL ≥ 2 kΩ.
Table 1.
Parameter
TRANSFER FUNCTION
MULTIPLIER PERFORMANCE
Total Error
TMIN to TMAX
Scale Voltage Error
Supply Rejection
Nonlinearity, X
Nonlinearity, Y
X Feedthrough
Y Feedthrough
Output Offset Voltage
DYNAMICS
Small Signal Bandwidth
Slew Rate
Settling Time to 1%
OUTPUT NOISE
Spectral Density
Wideband Noise
OUTPUT
Output Voltage Swing
Short Circuit Current
INPUT AMPLIFIERS
Signal Voltage Range
Offset Voltage (X, Y)
CMRR (X, Y)
Bias Current (X, Y, Z)
Differential Resistance
POWER SUPPLY
Supply Voltage
Rated Performance
Operating Range
Supply Current
Conditions
−10 V ≤ X, Y ≤ +10 V
SF = 10.00 V nominal
VS = ±14 V to ±16 V
X = ±10 V, Y = +10 V
Y = ±10 V, X = +10 V
Y nulled, X = ±10 V
X nulled, Y = ±10 V
VO = 0.1 V rms
VO = 20 V p-p
ΔVO = 20 V
f = 10 Hz to 5 MHz
f = 10 Hz to 10 kHz
RL = 0 Ω
Differential
Common mode
VCM = ±10 V, f = 50 Hz
Quiescent
AD633J, AD633A
Min
Typ
Max
(X1 − X2)(Y1 − Y2)
W=
+Z
10 V
±1
±3
±0.25%
±0.01
±0.4
±0.1
±0.3
±0.1
±5
1
20
2
±21
±11
±0.41
±11
±0.41
±501
0.8
1
90
±111
30
±101
±101
±5
601
80
0.8
10
401
±301
2.01
Unit
% full scale
% full scale
% full scale
% full scale
% full scale
% full scale
% full scale
% full scale
mV
MHz
V/µs
µs
µV/√Hz
mV rms
µV rms
V
mA
V
V
mV
dB
µA
MΩ
±15
±81
4
V
±181
V
61
mA
1 This specification was tested on all production units at electrical test. Results from those tests are used to calculate outgoing quality levels. All minimum and maximum