datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

MAL213694105E3 데이터 시트보기 (PDF) - Vishay Semiconductors

부품명
상세내역
일치하는 목록
MAL213694105E3 Datasheet PDF : 11 Pages
1 2 3 4 5 6 7 8 9 10
www.vishay.com
136 RVI
Vishay BCcomponents
3.8
IA 3.7
IR 3.6
3.5
3.4
3.3
3.2
3.1
3.0
CCC206
2.8
Lifetime multiplier
2.6
2.4
2.2
2.0
IA = Actual ripple current at 100 Hz
IR = Rated ripple current at 100 Hz, 105 °C
(1) Useful life at 105 °C and IR applied;
see Table 3
1.8
1.6
1.4
1.2
1.0
0.8
0.5
0.0
40
50
60
70
80
90
Fig. 14 - Multiplier of useful life as a function of ambient temperature and ripple current load
(1)
100 110
Tamb (°C)
Table 4
MULTIPLIER OF RIPPLE CURRENT (IR) AS A FUNCTION OF FREQUENCY
FREQ.
CODE
100
FREQUENCY (Hz)
300
1000
3000
10 000
IR MULTIPLIER
MF1
0.70
0.80
0.88
0.92
0.96
MF2
0.83
0.90
0.95
0.98
0.99
MF3
0.63
0.72
0.80
0.88
0.92
MF4
0.69
0.79
0.87
0.92
0.96
MF5
0.50
0.61
0.72
0.81
0.88
MF6
0.60
0.71
0.80
0.88
0.93
MF7
0.35
0.51
0.66
0.76
0.85
MF8
0.50
0.64
0.74
0.83
0.90
30 000
0.99
1.00
0.98
0.99
0.94
0.96
0.92
0.95
100 000
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
Table 5
TEST PROCEDURES AND REQUIREMENTS
TEST
NAME OF TEST
Endurance
REFERENCE
IEC 60384-4 / EN130300
subclause 4.13
PROCEDURE
(quick reference)
Tamb = 105 °C; UR applied;
for test duration see Table 3
Useful life
Shelf life
(storage at high
temperature)
CECC 30301
subclause 1.8.1
Tamb = 105 °C; UR and IR applied;
for test duration see Table 3
IEC 60384-4 / EN130300
subclause 4.17
Tamb = 105 °C; no voltage applied;
1000 h
after test: UR to be applied for 30 min,
24 h to 48 h before measurement
REQUIREMENTS
C/C: ± 20 %
tan   2 x spec. limit
IL2 spec. limit
C/C: ± 30 %
tan  3 x spec. limit
IL2 spec. limit
no short or open circuit
total failure percentage: 1 %
C/C: ± 20 %
tan  2 x spec. limit
IL2 spec. limit
Statements about product lifetime are based on calculations and internal testing. They should only be interpreted as estimations. Also due to external factors, the
lifetime in the field application may deviate from the calculated lifetime. In general, nothing stated herein shall be construed as a guarantee of durability.
Revision: 16-Sep-16
10
Document Number: 28321
For technical questions, contact: aluminumcaps1@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000