Philips Semiconductors
J1850/VPW transceiver with supply control function
Preliminary specification
AU5783
PINNING
Pin configuration
R/F 1
GND 2
4X/LOOP 3
NSTB 4
TX 5
RX 6
N.C. 7
14 GND
13 N.C.
12 BUS
AU5783
11 LOAD
10 INH
9
LWAKE
8
BAT
SO14
SL01225
Figure 2. Pin configuration
Pin description
SYMBOL PIN
DESCRIPTION
R/F
1 Rise/fall time control input; connect to ground
potential via a resistor
GND
2 Ground
4X/LOOP 3 Tx mode control input; low: normal mode;
high: 4X mode; float: loopback
NSTB
4 Network STandBy power control input; low:
transmit function disabled (low power modes);
high: transmit function enabled
TX
5 Transmit data input; low: transmitter passive;
high: transmitter active
RX
6 Receive data output; low: active bus condition
detected; high: otherwise
N.C.
7 Not connected
BAT
8 Battery supply input, 12V nominal
LWAKE
9 Local wake-up input, edge sensitive
INH
10 Activity indication flag (inhibit) output high side
driver; e.g., to control a voltage regulator.
Active high enables the regulator
LOAD
11 Bus load in/output
BUS
12 Bus line transmit/receive input/output, active
high side driver
N.C.
13 Not connected
GND
14 Ground
FUNCTIONAL DESCRIPTION
The AU5783 is an integrated line transceiver IC that interfaces an
SAE/J1850 protocol controller IC to the vehicle’s multiplex bus line.
It is primarily intended for automotive “Class B” multiplexing
applications in passenger cars using VPW (Variable Pulse Width)
modulated signals with a nominal transmission speed of 10.4 kbit/s.
The device provides transmit and receive capability as well as
protection to a J1850 electronic module.
A J1850 link controller feeds the transmit data stream to the
transceiver’s TX input. The AU5783 transceiver waveshapes the TX
data input signal so as to minimize electromagnetic emission. The
bus output signal features controlled rise & fall characteristic
including rounded shape. A resistance being connected to the R/F
control input sets the bus output slew rate.
The LOAD output is connected to the physical bus line via an
external load resistor Rld. The load resistor pulls the bus line to
ground potential being the default state, e.g., when no transmitter
outputs an active state. This output ensures the J1850 network will
not be affected by a potential loss of ground condition at an
individual electronic control unit.
The AU5783 includes a bus receiver with filter function to minimize
susceptibility against interference. The logic state of the J1850 bus
signal is indicated at the RX output being connected to the J1850
link controller.
The AU5783 also provides advanced low-power modes to help
minimize ignition-off power consumption of an electronic control unit.
The bus receiver function is kept alive in the low-power modes. If an
active state is being detected on the bus line this will be indicated
via the RX output. By default the AU5783 enters the low-power
standby mode when the mode control inputs NSTB and 4X/LOOP
are not driven. A 100 kpull down resistor is required on NSTB.
Ignition-off current draw can be reduced further by turning off the
voltage regulator being typically provided in an electronic control
unit. This is supported by the activity indication function of the
AU5783. In this application the activity indication flag INH will control
external devices such as a voltage regulator. To turn-off the INH flag
and thus the voltage regulator, the go to sleep command needs to
be applied to the Network Standby power control input,
e.g., NSTB = 0. The INH output is turned off after the sleep time-out
period thereby, reducing the power consumption of an electronic
control unit to an extremely low level.
The activity indication flag INH will be turned on again upon
detection of a remote wake-up condition (i.e. bus activity) or upon
detection of a local wake-up condition or a respective command
from the microcontroller. A local wake-up condition is detected
when an edge occurs at the wake-up input LWAKE. The INH flag
will also be turned on upon detection of a high input level at the
mode control input NSTB. Activation of the INH output enables
external devices, e.g., a voltage regulator. This condition will power-up
logic devices, e.g., a microcontroller in order to perform appropriate
action, e.g., activation of the AU5783 and the J1850 network.
The AU5783 contain a power on reset (POR) circuit, which is active
at low voltages. This circuit insures that if the control input NSTB is
at 0 V or floating during power up, the device will be forced into the
standby mode by the time the battery voltage rises to 4.4 V. This will
also insure that the INH pin is in the high state to turn on the local
voltage regulator. If there is a dip going below 4.4 V in battery
voltage while in the sleep mode, the device may return to the
2001 Feb 15
4

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]