Electrical Characteristics (Cont’d): (VI = –19V, IO = 40mA, CI = 0.33µF, CO = 0.1µF,
0° ≤ TJ ≤ +125°C, Note 2 unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Load Regulation
Regload TJ = +25°C, 1mA ≤ IO ≤ 100mA
–
– 100 mV
Quiescent Current
IB IO = 100mA
–
2
6 mA
Quiescent Current Change
∆IB With line, –27V ≤ VI ≤ –14.8V
–
– 0.25 mA
With load, 1mA ≤ IO ≤ 40mA
–
– 0.1 mA
Output Noise Voltage
Ripple Rejection
Input Voltage Required to
Maintain Line Regulation
Vn
RR
TCVO
TJ = +25°C, f = 10Hz to 10kHz
–25V ≤ VI ≤ –15V, f = 120Hz
TJ = +25°C
– 96 – µV
52 –
– dB
–
– –14.5 V
Note 2. To ensure constant junction temperature, low duty cycle pulse testing is used.
.210
(5.33)
Max
.135 (3.45) Min
Seating Plane
.500
(12.7)
Min
GND
VOUT
VIN
.021 (.445) Dia Max
.100 (2.54)
.050 (1.27)
.105 (2.67) Max
.205 (5.2) Max
.165 (4.2) Max
.105 (2.67) Max