datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

V24B48T250BN3 데이터 시트보기 (PDF) - Vicor

부품명
상세내역
일치하는 목록
V24B48T250BN3
Vicor
Vicor Vicor
V24B48T250BN3 Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
24V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Operating input voltage
18
24
36
VDC
Input surge withstand
50
VDC
Undervoltage turn-on
17.5
17.9
VDC
Undervoltage turn-off
14.8
15.3
VDC
Overvoltage turn-off/on
36.3
37.8
39.6
VDC
Disabled input current
4.0
VDC
Notes
<100ms
PC pin low
MODULE OUTPUT SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Output voltage setpoint
±1
%
Line regulation
±0.02
±0.20
%
Temperature regulation
±0.002
±0.005
% / °C
Power sharing accuracy
±2
±5
%
Programming range
10
110
%
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
3.3V
5V
6.5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 4.7
VDC
-0.5 to 7.0
VDC
-0.5 to 9.1
VDC
-0.5 to 10.9
VDC
-0.5 to 16.1
VDC
-0.5 to 20.0
VDC
-0.5 to 31.7
VDC
-0.5 to 36.9
VDC
-0.5 to 47.1
VDC
-0.5 to 62.9
VDC
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 10.
THERMAL RESISTANCE AND CAPACITY
Parameter
Min
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Typ
Max
0.16
0.14
8.0
1.9
83
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
24V Mini Family
Page 2 of 15
Rev 5.1
06/2017
vicorpower.com
800 927.9474

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]