MAP140 SERIES
OUTPUT SPECIFICATIONS
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
CONDITIONS/DESCRIPTION
MIN
Full load, 110 VAC. Varies with distribution of loads among outputs.
65
Single output models.
0
MAP140-3000P, total output current of V1 + V2 (Note 1).
2
Full load, 20MHz bandwidth.
Single output models.
MAP140-3000P with convection cooling.
MAP140-3000P with 200 LFM forced air cooling.
Output voltage overshoot/undershoot at turn-on/turn-off.
Varies by output. Total regulation includes: line changes from 90-132 VAC or 175-264,
changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation.
Time required for initial output voltage stabilization.
MAP140-3000P
Single output models
Time required for output voltage to rise from 10% to 90%.
NOTES: 1) Minimum load is required only to meet the regulation limits of V3.
NOM
MAX
UNITS
70
80
%
Amps
See Model Selection Chart.
See Model Selection Chart.
80
Watts
140
0
V
See Model Selection Chart.
500
µS
1
Sec
2
20
mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
Overvoltage Protection
Overload Protection
Remote Sense
Input Power Fail
Warning
Overtemperature Protection
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
Provided on single output models
and V1 of MAP140-3000P.
MAP140-3000P, V1
6.1
7.2
MAP140-1012
17.3
20.2
MAP140-1024
32.2
37.8
MAP140-1048
55.2
64.8
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
Voltage drop compensated for at the load.
250
TTL compatible logic signal. Time before regulation dropout due
to loss of input power at 140 watts, 110 VAC. Standard on MAP140-3000P
2.3
and optional on MAP140-1012.
Optional signal provides system shutdown due to excessive internal temperature. See options.
UNITS
V
mV
mS
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic
Interference, Conducted
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TÜV).
Input to output, 1 second.
FCC CFR title 47 part 15 sub-part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
Per EN61000-4-5, class 3.
Insulation Resistance
Leakage Current
Input to Output.
Per EN60950, 264VAC.
Line to Line
Line to Ground
110 VAC
264 VAC
MIN
2600
B
B
8
10
±2
1
2
10
NOM
MAX
Approved
0.5
1.5
UNITS
VDC
Class
kV
V/M
kV
kV
M
mA
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
Altitude
Operating Temperature
CONDITIONS/DESCRIPTION
Operating.
Non-operating.
Derate linearly above 50°C by 2.5% per °C
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
0°C to 70°C (after 15 minute warm-up period).
Non-condensing.
Operating, peak acceleration.
Random vibration, 10Hz to 2kHz, 3 axis.
At 100% load:
At 50% load:
MIN
NOM
MAX
UNITS
10k ASL Ft.
40k ASL Ft.
0
50
°C
0
70
°C
-40
85
°C
±0.02 ±0.05 %/°C
95
%RH
20
GPK
6
GRMS
2

Share Link: 