MB86615
2.6.4 Clearing the ISO Transmission/Reception FIFO Buffer Using the fifo-clr Bit
The ISO transmission/reception FIFO buffer is cleared by setting the fifo-clr bit (bit 4) in the ISO-FIFO control
register (address 0Eh) to “1.” Given below is a timing chart for the isochronous interface when the FIFO buffer
is cleared.
Note that this FIFO buffer clear function is available only when the point-rec bit (bit 7) or length-chk bit (bit 6)
in the ISO-FIFO control register has been set to “1.”
Parameter
IV rise to ILWRE rise
ILWRE negate time
Symbol
tCLR
tWREH
Min.
Value
Max.
4 tICLK
7 tICLK
Unit
ns
ns
ILWRE
tCLR
tWREH
IV
* : The ISO transmission/reception FIFO buffer is cleared while the ILWRE signal is negated.