Technical Terminology & Cautions for Use
MOUNTING STATE AND ENVIRONMENT
Checking the insulation distance
Soldering precautions
After mounting and wiring, check the insulation distance
For manual soldering, lay the terminals flat (horizontal with the
between terminals and the ground. If the insulation distance is
ground) and quickly perform the soldering operation using a
inadequate, mount insulating material between as required.
soldering iron with the appropriate heat capacity and the proper
Fastening the snap-action switch body
amount of solder. Take care that the flux does not flow into the
switch interior by using a ventilation fan to discharge flux gas
See the Section “CAUTIONS FOR USE” for the individual
and to prevent contact of the switch body with the soldering iron
switch.
tip.
Position adjustment with effector
Be careful not to apply force to the lead wires or the terminal
portions immediately after soldering.
1) The effector should be positioned so that direct force is not
The temperature setting and time conditions vary depending on
applied to the plunger or actuator in its free position. The
the product.
operating force to the plunger should only be applied in a
See the section “CAUTIONS FOR USE” for each product.
perpendicular direction.
2) Note that the use of the switch as a stopper may cause an
<Examples>
Soldering iron tip
operational problem.
Switch installation position
• Basically, the switch should be installed so that the object to
press the switch’s plunger or lever can press it down to 70 to
100% of OT of the switch. When determining the position, the
tolerance of OP (Operating Position) and other factors should be
taken into account.
The following describes the case where the strictest tolerance
conditions are adopted.
• Example: Hinge lever type FS switch
Reference values: OP = 8.8±0.8mm
PT = max. 2.8mm
OT = min. 1.2mm
FP
OP
PT
TTP
OT
(1) When the switch is not pressed
The object to press the lever should not be in contact with
the lever.
For this purpose, the object should be at a distance from
the switch father than the maximum FP (Free Position)
value.
FP max = OP max + PT max = 9.6 + 2.8 = 12.4 mm max
The object should be at a distance of 12.4 mm or more
from the mounting hole.
(2) Depressed position
The plunger/lever should be pressed down to 70% or
more of OT (Over Travel). Therefore, the depressed
position should be calculated based on the minimum
value of OP (Operating Position) and the 70 and 100% of
the OT value.
OP min - 70% of OT = 8.0 - 0.84 = 7.16 mm
OP min - 100% of OT = 8.0 - 1.2 = 6.80 mm
The plunger/lever should be pressed down to the position
of 6.80 to 7.16 mm from the mounting hole.
Wrong
Correct
Avoid using in a silicon atmosphere
Avoid using organic silicon rubber, adhesives, sealing
compounds, oil, grease, and wires in a silicon atmosphere.
Please consult us when using under the following
conditions*:
1) Environments where hydrogen sulfide or other corrosive
gases are present.
2) Environments where gasoline, thinner or other flammable,
explosive gases are present.
3) Dusty environments (for non-seal type snap action switches).
4) The perpendicular operating speed exceeds the allowable
operating speed.
5) Switching between different poles.
6) Use in environments not in the prescribed temperature or
humidity range.
Storage precautions
To prevent discoloration due to sulfurization of the terminals
(silver- plated), store the switches in a polyethylene bag or other
suitable airtight container.
–4–
AECTB36E 201701-T