datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

HC1HTM-AC6V-F 데이터 시트보기 (PDF) - Panasonic Corporation

부품명
상세내역
일치하는 목록
HC1HTM-AC6V-F
Panasonic
Panasonic Corporation Panasonic
HC1HTM-AC6V-F Datasheet PDF : 17 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
4) PC board type (with LED indication)
Coil voltage
1 Form C
Part No.
2 Form C
Part No.
3 Form C
Part No.
4 Form C
Part No.
6V AC
HC1-HPL-AC6V-F
HC2-HPL-AC6V-F
HC3-HPL-AC6V-F
HC4-HPL-AC6V
12V AC
HC1-HPL-AC12V-F
HC2-HPL-AC12V-F
HC3-HPL-AC12V-F
HC4-HPL-AC12V
24V AC
HC1-HPL-AC24V-F
HC2-HPL-AC24V-F
HC3-HPL-AC24V-F
HC4-HPL-AC24V
100/110V AC
HC1-HPL-AC100V-F
HC2-HPL-AC100V-F
HC3-HPL-AC100V-F
HC4-HPL-AC100V
110/120V AC
HC1-HPL-AC120V-F
HC2-HPL-AC120V-F
HC3-HPL-AC120V-F
HC4-HPL-AC120V
200/220V AC
HC1-HPL-AC200V-F
HC2-HPL-AC200V-F
HC3-HPL-AC200V-F
HC4-HPL-AC200V
6V DC
HC1-HPL-DC6V-F
HC2-HPL-DC6V-F
HC3-HPL-DC6V-F
HC4-HPL-DC6V
12V DC
HC1-HPL-DC12V-F
HC2-HPL-DC12V-F
HC3-HPL-DC12V-F
HC4-HPL-DC12V
24V DC
HC1-HPL-DC24V-F
HC2-HPL-DC24V-F
HC3-HPL-DC24V-F
HC4-HPL-DC24V
48V DC
HC1-HPL-DC48V-F
HC2-HPL-DC48V-F
HC3-HPL-DC48V-F
HC4-HPL-DC48V
100/110V DC
HC1-HPL-DC100V-F
HC2-HPL-DC100V-F
HC3-HPL-DC100V-F
HC4-HPL-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Note: Please add “-31” before “-F” in the part number when ordering the PC board type 0.9 mm width terminal (ex) HC1-HPL-AC6V-31-F.
HC
4 Form C (twin)
Part No.
HC4D-HPL-AC6V
HC4D-HPL-AC12V
HC4D-HPL-AC24V
HC4D-HPL-AC100V
HC4D-HPL-AC120V
HC4D-HPL-AC200V
HC4D-HPL-DC6V
HC4D-HPL-DC12V
HC4D-HPL-DC24V
HC4D-HPL-DC48V
HC4D-HPL-DC100V
5) TM type
Coil voltage
1 Form C
Part No.
6V AC
HC1-HTM-AC6V-F
12V AC
HC1-HTM-AC12V-F
24V AC
HC1-HTM-AC24V-F
48V AC
HC1-HTM-AC48V-F
100/110V AC
HC1-HTM-AC100V-F
110/120V AC
HC1-HTM-AC120V-F
200/220V AC
HC1-HTM-AC200V-F
6V DC
HC1-HTM-DC6V-F
12V DC
HC1-HTM-DC12V-F
24V DC
HC1-HTM-DC24V-F
48V DC
HC1-HTM-DC48V-F
100/110V DC
HC1-HTM-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2 Form C
Part No.
HC2-HTM-AC6V-F
HC2-HTM-AC12V-F
HC2-HTM-AC24V-F
HC2-HTM-AC48V-F
HC2-HTM-AC100V-F
HC2-HTM-AC120V-F
HC2-HTM-AC200V-F
HC2-HTM-DC6V-F
HC2-HTM-DC12V-F
HC2-HTM-DC24V-F
HC2-HTM-DC48V-F
HC2-HTM-DC100V-F
3 Form C
Part No.
HC3-HTM-AC6V-F
HC3-HTM-AC12V-F
HC3-HTM-AC24V-F
HC3-HTM-AC48V-F
HC3-HTM-AC100V-F
HC3-HTM-AC120V-F
HC3-HTM-AC200V-F
HC3-HTM-DC6V-F
HC3-HTM-DC12V-F
HC3-HTM-DC24V-F
HC3-HTM-DC48V-F
HC3-HTM-DC100V-F
4 Form C
Part No.
HC4-HTM-AC6V
HC4-HTM-AC12V
HC4-HTM-AC24V
HC4-HTM-AC48V
HC4-HTM-AC100V
HC4-HTM-AC120V
HC4-HTM-AC200V
HC4-HTM-DC6V
HC4-HTM-DC12V
HC4-HTM-DC24V
HC4-HTM-DC48V
HC4-HTM-DC100V
4 Form C (twin)
Part No.
HC4D-HTM-AC6V
HC4D-HTM-AC12V
HC4D-HTM-AC24V
HC4D-HTM-AC48V
HC4D-HTM-AC100V
HC4D-HTM-AC120V
HC4D-HTM-AC200V
HC4D-HTM-DC6V
HC4D-HTM-DC12V
HC4D-HTM-DC24V
HC4D-HTM-DC48V
HC4D-HTM-DC100V
RATING
1. Coil data
1) AC coils (50/60Hz)
Type
Standard
Nominal coil Pick-up voltage
voltage
(at 20°C 68°F)
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
80%V or less of
nominal voltage
(Initial)
Drop-out
voltage
(at 20°C 68°F)
30%V or more
of nominal
voltage
(Initial)
Nominal coil current
[±20%] (at 20°C 68°F)
50Hz
60Hz
224mA
111mA
56mA
28mA
13.4/14.7mA
12.2/13.5mA
6.7/7.4mA
200mA
100mA
50mA
25mA
12/13.2mA
10.9/11.9mA
6/6.6mA
Coil inductance
N.C.
condition
0.078H
0.312H
1.243H
4.974H
23.75H
27.19H
85.98H
N.O.
condition
0.074H
0.295H
1.181H
4.145H
20.63H
25.57H
81.76H
Nominal operating
power
50Hz
60Hz
1.3VA
1.3VA
1.3VA
1.3VA
1.3VA
1.3VA
1.3VA
1.2VA
1.2VA
1.2VA
1.2VA
1.2VA
1.2VA
1.2VA
Max. allowable
voltage
(at 70°C 158°F)
110%V of
nominal voltage
Notes: 1. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage. In particular, for AC operation, if the applied voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will flow
leading possibly to coil burnout.
2. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.
2) DC coils
Type
Standard
Nominal coil
voltage
6V DC
12V DC
24V DC
48V DC
100/110V DC
Pick-up voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C 68°F)
10%V or more of
nominal voltage
(Initial)
Nominal coil current
[±10%]
(at 20°C 68°F)
150mA
75mA
37mA
18.5mA
10/11mA
Coil resistance
[±10%]
(at 20°C 68°F)
40
160
650
2,600
10,000
Nominal operating Max. allowable voltage
power
(at 70°C 158°F)
0.9W
0.9W
0.9W
0.9W
1.0W
110%V of
nominal voltage
Notes: 1. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate ±0.4% for every ±1°C change in temperature.
2. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
3. For use with 200 V DC, connect a 10 K(5W) resistor, in series, to the 100 V DC relay.
4. The maximum allowable impress voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous
operation. (This value differs depending on the ambient temperature. Please contact us for details.)
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

Share Link: 