MITSUBISHI <INTELLIGENT POWER MODULES>
PM75RSD060
FLAT-BASE TYPE
INSULATED PACKAGE
BRAKE PART
Symbol
VCE(sat)
VFM
ICES
Parameter
Collector-Emitter
Saturation Voltage
FWDi Forward Voltage
Collector-Emitter
Cutoff Current
Test Condition
Min.
VD = 15V, IC = 30A
Tj = 25°C
—
VCIN = 0V, Pulsed
(Fig. 1) Tj = 125°C
—
IF = 30A
(Fig. 2) —
Tj = 25°C
—
VCE = VCES, VCIN = 15V
(Fig. 4) Tj = 125°C
—
Limits
Typ.
1.8
1.9
2.5
—
—
Max. Unit
2.5
2.6
V
3.5
V
1
10
mA
CONTROL PART
Symbol
Parameter
Test Condition
Limits
Min.
Typ.
Max. Unit
ID
Circuit Current
VD = 15V, VCIN = 15V
VN1-VNC
—
VXP1-VXPC
—
44
60
mA
13
18
Vth(ON) Input ON Threshold Voltage Applied between : UP-VUPC, VP-VVPC, WP-VWPC
Vth(OFF) Input OFF Threshold Voltage
UN • VN • WN • Br-VNC
1.2
1.5
1.8
V
1.7
2.0
2.3
OC
Over Current Trip Level
Inverter part
VD = 15V
(Fig. 5,6)
Tj = –20°C
Tj = 25°C
Tj = 125°C
—
—
380
192
226
320
115
—
—
A
Break part
–20 ≤ Tj ≤ 125°C, VD = 15V
39
53
—
(Fig. 5,6)
SC
Short Circuit Trip Level
Inverter part
—
–20≤ Tj ≤ 125°C, VD = 15V (Fig. 5,6) Brake part
—
241
—
A
79
—
toff(OC) Over Current Delay Time
VD = 15V
(Fig. 5,6) —
10
—
µs
OT
OTr
Base-plate
Over Temperature Protection
Temperature detection, VD = 15V
Trip level
Reset level
111
118
125
°C
—
100
—
UV
UVr
Supply Circuit Under-Voltage
Protection
–20 ≤ Tj ≤ 125°C
Trip level
Reset level
11.5
12.0 12.5
V
—
12.5
—
IFO(H)
IFO(L)
Fault Output Current
VD = 15V, VFO = 15V
(Note-3)
—
—
—
0.01
mA
10
15
Minimum Fault Output Pulse
tFO
Width
VD = 15V
(Note-3) 1.0
1.8
—
ms
(Note-3) Fault output is given only when the internal OC, SC, OT & UV protection.
Fault output of OC, SC and UV protection operate by upper and lower arms.
Fault output of OT protection operate by lower arm.
Fault output of OC, SC protection given pulse.
Fault output of OT, UV protection given pulse while over level.
MECHANICAL RATINGS AND CHARACTERISTICS
Symbol
—
—
—
Parameter
Mounting torque
Mounting torque
Weight
Main terminal
Mounting part
Test Condition
—
Limits
Min.
Typ.
Unit
Max.
screw : M5
2.5
3.0
3.5 N • m
screw : M5
2.5
3.0
3.5 N • m
—
560
—
g
RECOMMENDED CONDITIONS FOR USE
Symbol
Parameter
VCC
Supply Voltage
VD
Control Supply Voltage
VCIN(ON) Input ON Voltage
VCIN(OFF) Input OFF Voltage
fPWM
PWM Input Frequency
tdead
Arm Shoot-through
Blocking Time
Test Condition
Applied across P-N terminals
Applied between : VUP1-VUPC, VVP1-VVPC
VWP1-VWPC, VN1-VNC
(Note-4)
Applied between : UP-VUPC, VP-VVPC, WP-VWPC
UN • VN • WN • Br-VNC
Using Application Circuit input signal of IPM, 3φ
sinusoidal PWM VVVF inverter
(Fig. 8)
For IPM’s each input signals
(Fig. 7)
(Note-4) Allowable Ripple rating of Control Voltage : dv/dt ≤ ±5V/µs, 2Vp-p
Recommended value
Unit
≤ 400
V
15 ± 1.5
V
≤ 0.8
V
≥ 4.0
≤ 20
kHz
≥ 2.5
µs
Jul. 2005