datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

PM50CSD120 데이터 시트보기 (PDF) - MITSUBISHI ELECTRIC

부품명
상세내역
일치하는 목록
PM50CSD120
Mitsubishi
MITSUBISHI ELECTRIC  Mitsubishi
PM50CSD120 Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
MITSUBISHI <INTELLIGENT POWER MODULES>
PM50CSD120
FLAT-BASE TYPE
INSULATED PACKAGE
CONTROL PART
Symbol
Parameter
Test Condition
Limits
Min.
Typ.
Max. Unit
ID
Circuit Current
VD = 15V, VCIN = 15V
VN1-VNC
40
55
mA
VXP1-VXPC
13
18
Vth(on)
Vth(off)
Input ON Threshold Voltage Applied between : UP-VUPC, VP-VVPC, WP-VWPC
Input OFF Threshold Voltage
UN VN WN-VNC
1.2
1.5
1.8
V
1.7
2.0
2.3
OC
Over Current Trip Level
VD = 15V
Tj = 25°C
(Fig. 5,6) Tj = 125°C
93
157
59
A
SC
toff(OC)
Short Circuit Trip Level
Over Current Delay Time
20Tj 125°C, VD = 15V
VD = 15V
(Fig. 5,6)
(Fig. 5,6)
183
A
10
µs
OT
Base-plate
Trip level
Over Temperature Protection
OTr
Temperature detection, VD = 15V
Reset level
111
118
125
100
°C
UV
Supply Circuit Under-Voltage 20 Tj 125°C
UVr
Protection
Trip level
Reset level
11.5
12.0
12.5
12.5
V
IFO(H)
IFO(L)
Fault Output Current
VD = 15V, VFO = 15V
(Note-3)
0.01
mA
10
15
tFO
Minimum Fault Output Pulse VD = 15V
Width
(Note-3) 1.0
1.8
ms
(Note-3) Fault output is given only when the internal OC, SC, OT & UV protection.
Fault output of OC, SC and UV protection operate by upper and lower arms.
Fault output of OT protection operate by lower arm.
Fault output of OC, SC protection given pulse.
Fault output of OT, UV protection given pulse while over level.
MECHANICAL RATINGS AND CHARACTERISTICS
Symbol
Parameter
Mounting torque
Mounting torque
Weight
Main terminal
Mounting part
Test Condition
Limits
Min.
Typ.
Unit
Max.
screw : M5
2.5
3.0
3.5 N m
screw : M5
2.5
3.0
3.5 N m
560
g
RECOMMENDED CONDITIONS FOR USE
Symbol
Parameter
VCC
Supply Voltage
VD
Control Supply Voltage
VCIN(on)
VCIN(off)
Input ON Voltage
Input OFF Voltage
fPWM
PWM Input Frequency
tdead
Arm Shoot-through
Blocking Time
Test Condition
Recommended value
Unit
Applied across P-N terminals
800
V
Applied between : VUP1-VUPC, VVP1-VVPC
VWP1-VWPC, VN1-VNC
(Note-4)
15 ± 1.5
V
Applied between : UP-VUPC, VP-VVPC, WP-VWPC
UN VN WN-VNC
0.8
4.0
V
Using Application Circuit input signal of IPM, 3φ
sinusoidal PWM VVVF inverter
(Fig. 8)
20
kHz
For IPMs each input signals
(Fig. 7)
3.0
µs
(Note-4) Allowable Ripple rating of Control Voltage : dv/dt ≤ ±5V/µs, 2Vp-p
Jul. 2005